About The Drug Calcium Hydroxylapatite Gel Filler for Wrinkle Reduction aka Radiesse

ClusterMed

Find Calcium Hydroxylapatite Gel Filler for Wrinkle Reduction side effects, uses, warnings, interactions and indications. Calcium Hydroxylapatite Gel Filler for Wrinkle Reduction is also known as Radiesse.

Calcium Hydroxylapatite Gel Filler for Wrinkle Reduction

Calcium Hydroxylapatite Gel Filler for Wrinkle Reduction Prescription Drug Bottle
About Calcium Hydroxylapatite Gel Filler for Wrinkle Reduction aka Radiesse

What's The Definition Of The Medical Condition Calcium Hydroxylapatite Gel Filler for Wrinkle Reduction?

Clinical Pharmacology

CLINICAL PHARMACOLOGY Clinical Studies Nasolabial Fold Pre-Market Clinical Trial Study Design The safety and effectiveness of RADIESSE injectable implant for the treatment of nasolabial folds (NLFs) was evaluated in a multi-center, prospective, randomized clinical trial. Patients were randomized to receive RADIESSE injectable implant in one fold and a commercially available collagen implant in the contralateral fold. Patients were eligible to receive up to three injections during the initial treatment phase (week 0, week 2 and week 4). At 2 weeks after each treatment, the level of correction was determined and if correction was less than optimal, the Investigator re-treated the nasolabial fold using the same respective treatment materials as in the initial treatment. A safety follow-up was conducted 1 month after any injection and at 3 and 6 months after the last injection. Effectiveness evaluations were conducted at 3 and 6 months after the last injection. Three blinded reviewers independently evaluated the severity of the subject's nasolabial folds using a validated 6-point wrinkle severity scale. Study Endpoints The primary effectiveness endpoint of the study was the blinded reviewers' Lemperle Rating Scale (LRS) score of wrinkle severity at 3 months after the last touch-up (at which optimal correction was achieved). In this assessment, LRS scores were determined, (using this validated 6-point scale), via blinded, photographic assessments by 3 board certified physicians. A change in LRS of 1 was considered to be clinically significant. Secondary effectiveness endpoints included the blinded reviewers' assessment of wrinkle severity at 6 months after treatment, and the volume of material injected. Study Population A total of 117 subjects (31-76 years of age) were randomized and treated and 115 (98.3%) completed the 3 month primary effectiveness evaluation and 113 (96.6%) completed the 6 month follow-up visit. The baseline demographics of the study population are presented in Table 7 which shows that the study enrolled a population of predominantly female, Caucasian nonsmokers. Table 7: PATIENT DEMOGRAPHICS N = 117 AGE (YEARS) Mean 54.7 Standard Deviation 8.9 Minimum 31.0 Maximum 76.0 GENDER Female 105 (89.7%) Male 12 (10.3%) RACE American Indian 0 (0.0%) Asian 0 (0.0%) Black 2 (1.7%) Caucasian 102 (87.2%) Hispanic 11 (9.4%) Other 2 (1.7%) SMOKING HISTORY Quit Smoking 26 (22.2%) Never Smoked 83 (70.0%) Smokes 8 (6.8%) Treatment Material Delivered Volumes injected during the initial treatment phase are detailed in Table 8 below. The total mean volume for RADIESSE injectable implant was 1.2mL and 2.4mL for the Control. Table 8: TOTAL VOLUME OF MATERIAL INJECTED (mL), N = 117 RADIESSE® CONTROL Mean 1.2 2.4 Median 1.1 2.2 Standard Deviation 0.5 0.9 Minimum 0.3 0.8 Maximum 2.7 4.7 Effectiveness Results Table 9 contains the mean LRS at baseline, 3 months and 6 months for the RADIESSE injectable implant treated nasolabial folds and the Control treated nasolabial folds with the difference between the means. Baseline scores for the RADIESSE injectable implant and Control groups were not statistically different. Table 9: COMPARISON OF MEAN LRS SCORES* FOR RADIESSE INJECTABLE IMPLANT AND CONTROL Nasolabial Folds - Baseline, 3 and 6 Months RADIESSE® CONTROL DIFFERENCE Baseline 3.4 3.4 0.0 3 Months 1.9 3.5 1.6 6 Months 2.1 3.4 1.3 * Grading Scale: 0 = No wrinkles, 1 = Just perceptible wrinkle, 2 = Shallow wrinkle, 3 = Moderately deep wrinkle, 4 = Deep wrinkle, well-defined edges, 5 = Very deep wrinkle, redundant fold Primary Effectiveness Endpoint The primary effectiveness endpoint was to use mean LRS scores to evaluate whether RADIESSE injectable implant was non-inferior to Control for the correction of nasolabial folds 3 months after final treatment. At 3 months, 84.6% of the RADIESSE injectable implant treated nasolabial folds were scored at least 1-point higher than the Control, 12.8% were scored equally, and 2.6% were scored at least 1-point lower than the Control. RADIESSE injectable implant met the statistical criteria for non-inferiority to Control at 3 months (p < 0.0001), however, the Control scored no effectiveness at 3 months. Secondary Effectiveness Endpoint The pre-specified secondary superiority analyses at 6 months required a mean 1-point LRS difference between the improvements for the RADIESSE injectable implant treated nasolabial fold versus improvement on the Control treated nasolabial fold and that in at least 50% of patients, the RADIESSE injectable implant treated nasolabial fold be superior to the Control treated nasolabial fold. At 6 months after optimal correction was achieved, 78.6% of the RADIESSE injectable implant treated nasolabial folds were scored at least 1-point higher than the Control-treated folds, 16.2% were scored equally, and 5.1% were scored at least 1-point lower than the Control. The mean LRS for the RADIESSE injectable implant treated nasolabial folds demonstrated superiority when compared to the mean LRS for the Control-treated nasolabial folds at 6 months (p < 0.0001). Nasolabial Folds Mixing Radiesse Injectable Implant With 2% Lidocaine Hcl Pre-Market Clinical Trial CAUTION: The clinical study that evaluated the mixing of 2% lidocaine and RADIESSE injectable implant was conducted ONLY on nasolabial folds. The safety and effectiveness for the mixing of 2% lidocaine and RADIESSE injectable implant for restoration and/or correction of the signs of facial fat loss (lipoatrophy) in people with human immunodeficiency virus has not been studied. In a prospective, randomized split-face single-blind clinical study, 50 patients were injected with syringes of 1.3cc of RADIESSE injectable implant mixed with 0.2cc of 2% lidocaine HCl (lidocaine) in one nasolabial fold (Treatment) and RADIESSE injectable implant without the 2% lidocaine (Control) in the contralateral nasolabial fold at two investigational sites in the United States. The purpose of this study was to assess the effectiveness of RADIESSE injectable implant mixed with 2% lidocaine for the reduction of pain during injection and the incidence of adverse events through the 1 month follow-up period. Study Endpoints The two primary effectiveness endpoints of the study were to evaluate if a statistically significant reduction in pain existed in the Treatment nasolabial fold when compared to the Control nasolabial fold immediately after treatment using a validated visual analog scale (VAS) and to assess whether the observed differences in pain in the Treatment nasolabial fold when compared to the Control nasolabial fold were clinically meaningful immediately after treatment. The secondary effectiveness endpoints assessed pain in the Treatment nasolabial fold when compared to the Control nasolabial fold at various times out to 1 month post treatment, aesthetic effectiveness out to one month after treatment and subject preference by analyzing the percent of patients favoring one treatment over the other. Study Population The inclusion criteria for the clinical study were that the patient was at least 18 years of age, was a candidate for nasolabial fold treatment using RADIESSE injectable implant, understood and accepted the obligation not to receive any other facial procedures in the lower half of the face for 1 month, understood and accepted the obligation to present for all scheduled follow-up visits, was logistically able to meet all study requirements and had approximately symmetrical nasolabial folds. The exclusion criteria for the clinical study were patients that had received any type of treatment or procedures including surgery in the nasolabial folds, had received neurotoxins in the lower half of the face in the past 6 months, had received hyaluronic acid, calcium hydroxylapatite (CaHA) or collagen injections in the lower half of the face within the past 1 ½ years, had received polylactic acid, PMMA, silicone or any other permanent filler injections in the lower half of the face, had nasolabial folds that were too severe to be corrected in one treatment session, had a history of chronic or recurrent infection or inflammation that would preclude participation in the study, had a known bleeding disorder or were receiving medication that would likely increase the risk of bleeding, was female and of child bearing potential and was pregnant or not using acceptable method of birth control, had any history of hypersensitivity to Lidocaine or anesthetics of the amide type, had a history of anaphylaxis or multiple severe allergies, or had received any investigational product within 30 days prior to study enrollment or is planning to participate in another investigation during the course of this study. Study Results The first primary effectiveness endpoint of the study was to assess pain using the Visual Analog Scale (VAS) in the Treatment fold compared to the Control fold. The mean VAS scores at time zero resulted in a statistically significant reduction in pain in the Treatment fold compared to the Control fold. The mean difference in VAS scores was -3.85 and a paired t-test resulted in a pvalue of < 0.0001 (see Table 10). Table 10: VISUAL ANALOG SCALE (VAS) SCORE AT TIME ZERO TREATMENT CONTROL Mean 2.8 6.6 Median 2.5 7.0 St. Deviation 1.9 2.2 Minimum 0.0 2.0 Maximum 8.5 10.0 Mean Difference 3.85 p-value < 0.0001 The second primary effectiveness endpoint of the study was to assess percentage of patients in which there was a clinically meaningful reduction in pain in the Treatment fold. Forty-five (45) of the 50 patients (90%) recorded VAS scores of at least 2.0cm lower for the Treatment fold compared to the Control fold, demonstrating a clinically meaningful reduction in pain (see Table 11). Table 11: VAS SCORE ≥ 2.0cm LOWER IN TREATMENT VS. CONTROL N = 50 N % 45 90.0% C.I. 78.2%-96.7% p < 0.0001 A secondary effectiveness endpoint of the study was to assess pain in the Treatment fold compared to the Control fold at various times out to 1 month. The Treatment fold showed a statistically significant reduction in pain at four time points within the first hour (p < 0.0001) when compared to the Control fold. At 2 weeks and 1 month, there was no difference between the Treatment and Control folds as all pain ratings for both groups were 0 (no pain) (see Table 12). Table 12: VAS SCORE AFTER TIME ZERO N = 50 15 MIN 30 MIN 45 MIN 60 MIN 2 WEEK 1 MONTH TX CON- TROL TX CON- TROL TX CON- TROL TX CON- TROL TX CON- TROL TX CON- TROL Mean 0.9 3.4 0.7 2.5 0.5 1.8 0.3 1.3 0.0 0.0 0.0 0.0 Median 0.5 3.0 0.5 2.3 0.0 1.0 0.0 0.5 0.0 0.0 0.0 0.0 SD 1.0 2.2 1.0 2.1 0.8 1.8 0.7 1.6 0.0 0.0 0.0 0.0 Minimum 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Maximum 4.0 8.0 5.0 7.5 3.5 6.5 3.0 6.0 0.0 0.0 0.0 0.0 p-value < 0.0001 < 0.0001 < 0.0001 < 0.0001 N/A N/A Another effectiveness endpoint assessed aesthetic improvement on the Global Aesthetic Improvement Scale (GAIS) at 2 weeks and 1 month post treatment. All patients in both groups were at least “Improved” (see Table 13). Table 13: GAIS DISTRIBUTION RATING 2 WEEKS N (%) 1 MONTH N (%) TREATMENT CONTROL TREATMENT CONTROL Very Much Improved 29 (58.0) 26 (52.0) 31 (62.0) 28 (56.0) Much Improved 16 (32.0) 18 (36.0) 12 (24.0) 20 (40.0) Improved 5 (10.0) 6 (12.0) 0) 2 (4.0) No Change 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Worse 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) TOTAL IMPROVED 50 (100.0) 50 (100.0) 50 (100.0) 50 (100.0) p-value 1.0000 1.0000 Nasolabial Folds Long-Term Safety Post-Approval Study Study Objective A post approval study was performed to 1) collect long-term safety information on use of RADIESSE injectable implant injected into the nasolabial folds; and 2) to assess the effect of multiple injections. Study Design RADIESSE injectable implant was assessed in a prospective, open-label, multi-center study of patients whose nasolabial folds were corrected with RADIESSE injectable implant. 102 subjects (drawn from the 117 patients who participated in the premarket clinical trial) agreed to participate in the post approval study. Patients were requested to return for visits a minimum of 2 years and then a minimum of 3 years after their initial injection. At the beginning of the post marketing study, 8 patients were already 3 years from initial injection and, therefore, required only one visit. One hundred and two (102) patients were assessed a minimum of 2 years after initial injection and 99 were assessed a minimum of 3 years after initial injection. Three (3) patients were lost to follow up. Study Population The patient cohort in this post approval study was the continued follow-up of the pre-market cohort. Patient demographics are provided in Table 14. Table 14: PATIENT DEMOGRAPHICS N =102 AGE (YEARS) Mean 55.1 Standard Deviation 8.8 Minimum 31.0 Maximum 76.0 GENDER Female 94 (92.2%) Male 8 (7.8%) RACE American Indian 1 (1.0%) Asian 0 (0.0%) Black 1 (1.0%) Caucasian 8 .8 % Hispanic 11 (10.8%) Other 2 (2.0%) SMOKING HISTORY Quit Smoking 23 (22.6%) Never Smoked 73 (71.6%) Smokes 6 (5.9%) The inclusion criterion for the study was participation in the pre-market clinical trial (Section I of the Nasolabial Folds CLINICAL STUDIES section) and signing a written informed consent for participation in the post-approval study. There were no additional exclusion criteria. Study Endpoints To collect long-term safety information of RADIESSE injectable implant injected into the nasolabial folds at a minimum of 2 and 3 years after initial injection and to assess the effect of multiple injections. Study Results 102 study patients and 204 folds received a mean of 3.7 and 1.8 RADIESSE injections, respectively, from the time period covering initial pre market study injection through the last post approval study visit. 100% of patients and 98% of folds received RADIESSE treatment during the same time period with only 11% of patients receiving RADIESSE injections during the post approval study period alone. During the post approval study, 15% of patients received Botulinum toxin injections and 9% of patients received facial dermal fillers other than RADIESSE injectable implant in the nasolabial folds. With respect to the long term safety of RADIESSE injectable implant, there were no reports of long term adverse events in this post approval study. The adverse events monitored in the postapproval study included allergic reaction, ecchymosis, edema, embolization, erosion, erythema, extrusion, granuloma, hematoma, infection, necrosis, needle jamming, nodule, and pain. These results demonstrate the long term safety and effectiveness of RADIESSE injectable implant up to 3 years after the date of first injection. Study Limitations RADIESSE injectable implant was studied in a limited number of predominately female patients. Safety of RADIESSE injectable implant following the correction of nasolabial folds beyond 3 years was not studied. Nasolabial Folds Fitzpatrick Skin Type Iv-Vi Post-Approval Study Study Objective A post-approval study was performed to assess the safety of RADIESSE injectable implant following correction of the nasolabial folds in patients with Fitzpatrick Skin Types 4, 5, or 6, specifically to assess the likelihood of hypertrophic scarring, keloid formation and hyper- or hypopigmentation. Study Design The safety of RADIESSE injectable implant was assessed in a prospective, open-label, multicenter study in 100 patients with Fitzpatrick Skin Types 4, 5 or 6 whose nasolabial folds were corrected with subdermal injections of RADIESSE injectable implant. Study Population Patient demographics are provided in Table 15. Table 15: PATIENT DEMOGRAPHICS N = 100 AGE (YEARS) Mean 52 Standard Deviation 11.1 Minimum 25 Maximum 78 GENDER Male 6 (6.0%) Female 94 (94.0%) RACE Caucasian 0 (0.0%) Black 85 (85.0%) Hispanic 12 (12.0%) Asian 2 (2.0%) Other 1 (1.0%) FITZPATRICK SKIN TYPE 4 24(24.0%) 5 35(35.0%) 6 41(41.0%) INJECTION VOLUME (mL) Mean 1.24 Standard Deviation 0.397 Minimum 0.6 Maximum 2.8 The Inclusion Criteria for the post-approval study were that the patient was at least 18 years of age, has Fitzpatrick Skin Type IV, V, or VI, and understands and accepts the obligation not to receive any other procedures or treatments in the nasolabial fold for 6 months. The Exclusion Criteria for the post-approval study were that the patient has history of hyper- or hypo-pigmentation in the nasolabial folds, keloid formation, or hypertrophic scarring, has a known bleeding disorder or is receiving drug therapy that could increase the risk of bleeding, has nasolabial folds that are too severe to be corrected in one treatment session, has received any dermal filler or other injections, grafting or surgery in either nasolabial fold, is pregnant, lactating, or not using acceptable contraception. Study Endpoints The likelihood of hypertrophic scarring, keloid formation and hyper- or hypopigmentation was evaluated through 6 months from treatment with RADIESSE injectable implant in the nasolabial folds. Length of Follow-up and Assessments Patients were followed for 6 months from RADIESSE treatment (injection visit). Ninety days (90) ± 30 days from the injection visit, patients returned for a safety assessment of their nasolabial folds (3 month visit). One hundred eighty days (180) ± 30 days from the initial injection, patients returned for a safety assessment of their nasolabial folds (6 month visit). Subject Accountability One hundred (100) patients were enrolled in the post-approval study. 100 patients were assessed at the 3 month visit (100% follow-up rate). Ninety eight (98) patients were assessed at the 6 month visit (98% follow-up rate). Two (2) patients were lost to follow-up. Study Results At 3 months, 100% of patients were assessed and there were no reports of hypertrophic scarring, keloid formation, hyperpigmentation or hypopigmentation at the injection site. At 6 months 98% of patients were assessed. Two (2) patients were lost to follow-up. Of the 98 patients assessed, no occurrence of hypertrophic scarring, keloid formation, hyperpigmentation or hypopigmentation at the injection site was reported. One patient reported erythema in the upper left nasolabial fold that was treated with hydrocortisone and lasted for 111 days. Another patient experienced mild hyperpigmentation in the upper lip that lasted 159 days. No treatment was required. The use of RADIESSE injectable implant did not cause hypertrophic scarring, keloid formation, hyperpigmentation or hypopigmentation at the injection site in persons with Fitzpatrick Skin Types of 4, 5 and 6 in this study throughout the follow-up period of 6 months. Study Limitations RADIESSE injectable implant was studied in a limited number of predominately female patients. Likelihood of keloid formation, hypertrophic scarring, and hypo- or hyperpigmentation after use of RADIESSE injectable implant for the correction of nasolabial folds in patients with Fitzpatrick Skin Type 4, 5 and 6 beyond 6 months was not studied. Hiv-Associated Facial Lipoatrophy Pre-Market Clinical Trial In a 12-month prospective, open label study of 100 patients at three U.S. sites, adverse events reported after RADIESSE injectable implant treatments are presented below. Adverse events reported in patient diaries during the 14 days after treatment are listed in Tables 16 and 17. Physician reported adverse events (those reported by Investigators and patients any time outside the 2 week diaries) are presented in Tables 18 and 19. Table 16: PATIENT DIARY ADVERSE EVENTS Reported Through Patient Diaries Maximum Severity By Adverse Event Type N = 100 ADVERSE EVENT TYPE PATIENTS REPORTING SYMPTOMS MILD N (%) MODERATE N (%) SEVERE N (%) Ecchymosis 64 34 (53.1) 25 (39.1) 5 (7.8) Edema 99 46 (46.5) 49 (49.5) 4 (4.0) Erythema 55 32 (58.2) 23 (41.8) 0 (0.0) Granuloma 0 0 (0.0) 0 (0.0) 0 (0.0) Nodule 0 0 (0.0) 0 (0.0) 0 (0.0) Pain 37 24 (64.9) 13 (35.1) 0 (0.0) Pruritis 21 18 (85.7) 4.3 ) 0 (0.0) Contour Irregularity 11 8 (72.7) 3 (27.3) 0 (0.0) Discoloration 5 2 (40.0) 3 (60.0) 0 (0.0) Hardness 4 2 (50.0) 2 (50.0) 0 (0.0) Headache 3 1 (33.3) 2 (66.7) 0 (0.0) Lump 12 8 (66.7) 4 (33.3) 0 (0.0) * Other - Miscellaneous 13 9 (69.2) 4 (30.8) 0 (0.0) Numbness 4 4 (100) 0 (0.0) 0 (0.0) Scab 2 1 (50.0) 1 (50.0) 0 (0.0) Soreness 3 2 (66.7) 1 (33.3) 0 (0.0) Tenderness 3 3 (100) 0 (0.0) 0 (0.0) Tightness 2 1 (50.0) 0 (0.0) 1 (50.0) * 13 patients with the following event types: flushed, bloodshot eyes, fever, black eye, ear running, backed up salivary gland, spot, nerve sensitivity, dry, sinus infection, burning sensation, warm cheeks, felt stretched, rash. Table 17: PATIENT DIARY ADVERSE EVENTS Reported Through Patient Diaries Duration By Adverse Event Type N = 100 ADVERSE EVENT TYPE TOTAL REPORTING SYMPTOMS NUMBER OF DAYS 1-3 N (%) 4-7 N (%) 8-14 N (%) > 14 N (%) Ecchymosis 142 29 (20.4) 51 (35.9) 50 (35.2) 12 (8.5) Edema 431 206 (47.8) 153 (35.5) 52 (12.1) 20 (4.6) Erythema 210 114 (54.3) 69 (32.9) 22 (10.5) 5 (2.4) Granuloma 0 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Nodule 0 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Pain 110 54 (49.1) 32 (29.1) 18 (16.4) 6 (5.5) Pruritis 54 28 (51.9) 9 (16.7) 6 (11.1) 11 (20.4) Contour Irregularity 30 4 (13.3) 1 (3.3) 5 (16.7) 20 (66.7) Discoloration 6 2 (33.3) 0 (0.0) 2 (33.3) 2 (33.3) Hardness 8 2 (25.0) 1 (12.5) 2 (25.0) 3 (37.5) Headache 3 2 (66.7) 0 (0.0) 0 (0.0) 1 (33.3) Lump 18 6 (33.3) 2 (11.1) 4 (22.2) 6 (33.3) * Other - Miscellaneous 18 9 (50.0) 4 (22.2) 2 (11.1) 3 (16.7) Numbness 7 7 (100) 0 (0.0) 0 (0.0) 0 (0.0) Scab 4 1 (25.0) 2 (50.0) 1 (25.0) 0 (0.0) Soreness 6 3 (50.0) 3 (50.0) 0 (0.0) 0 (0.0) Tenderness 8 3 (37.5) 5 (62.5) 0 (0.0) 0 (0.0) Tightness 4 1 (25.0) 1 (25.0) 2 (50.0) 0 (0.0) * 18 reports of the following event types: flushed, bloodshot eyes, fever, black eye, ear running, backed up salivary gland, spot, nerve sensitivity, dry, sinus infection, burning sensation, warm cheeks, felt stretched, rash. Table 18: PHYSICIAN REPORTED ADVERSE EVENTS Maximum Severity By Adverse Event Type N = 100 ADVERSE EVENT TYPE PATIENTS REPORTING SYMPTOMS MILD N (%) MODERATE N (%) SEVERE N (%) Ecchymosis 3 2 (66.7) 1 (33.3) 0 (0.0) Edema 7 7 (100) 0 (0.0) 0 (0.0) Erythema 3 3 (100) 0 (0.0) 0 (0.0) Granuloma 0 0 (0.0) 0 (0.0) 0 (0.0) Needle Jamming 0 0 (0.0) 0 (0.0) 0 (0.0) Nodule 0 0 (0.0) 0 (0.0) 0 (0.0) Pain 2 1 (50.0) 0 (0.0) 1 (50.0) Pruritis 0 0 (0.0) 0 (0.0) 0 (0.0) Contour Irregularity 19 15 (78.9) 4 (21.1) 0 (0.0) Discoloration 3 3 (100) 0 (0.0) 0 (0.0) Lump 2 1 (50.0) 1 (50.0) 0 (0.0) * Other - Miscellaneous 5 2 (40.0) 3 (60.0) 0 (0.0) * 5 patients with the following event types: puffiness, hearing loss, skin tag/lesion excision, firmness. Table 19: PHYSICIAN REPORTED ADVERSE EVENTS Duration By Adverse Event Type N = 100 ADVERSE EVENT TYPE TOTAL REPORTING SYMPTOMS NUMBER OF DAYS 1-3 N (%) 4-7 N (%) 8-14 N (%) > 14 N (%) Ecchymosis 5 3 (60.0) 0 (0.0) 2 (40.0) 0 (0.0) Edema 12 9 (75.0) 1 (8.3) 1 (8.3) 1 (8.3) Erythema 4 1 (25.0) 2 (50.0) 0 (0.0) 1 (25.0) Granuloma 0 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Needle Jamming 0 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Nodule 0 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Pain 4 2 (50.0) 0 (0.0) 2 (50.0) 0 (0.0) Pruritis 0 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Contour Irregularity 44 22 (50.0) 0 (0.0) 1 (2.3) 21 (47.7) Discoloration 6 0 (0.0) 0 (0.0) 0 (0.0) 6 (100) Lump 3 1 (33.3) 0 (0.0) 0 (0.0) 2 (66.7) * Other - Miscellaneous 10 5 (50.0) 0 (0.0) 0 (0.0) 5 (50.0) * 10 reports of the following event types: puffiness, hearing loss, skin tag/lesion excision, firmness Hiv-Associated Facial Lipoatrophy Long-Term Safety Study Adverse events reported at 18 months are presented below. Adverse events reported in patient diaries during the 14 days after treatment are listed in Tables 20 and 21. Physician reported adverse events (those reported by Investigators and patients any time outside the 2 week diaries) are presented in Tables 22 and 23. Table 20: PATIENT DIARY ADVERSE EVENTS - 18 MONTHS Reported Through Patient Diaries Maximum Severity By Adverse Event Type N = 100 ADVERSE EVENT TYPE PATIENTS REPORTING SYMPTOMS MILD N (%) MODERATE N (%) SEVERE N (%) Ecchymosis 22 9 (40.9) 10 (45.5) 3 (13.6) Edema 74 47 (63.5) 23 (31.1) 4 (5.4) Erythema 40 25 (62.5) 14 (35.0) 1 (2.5) Granuloma 0 0 (0.0) 0 (0.0) 0 (0.0) Nodule 0 0 (0.0) 0 (0.0) 0 (0.0) Pain 23 12 (52.2) 11 (47.8) 0 (0.0) Pruritis 7 7 (100) 0 (0.0) 0 (0.0) Contour Irregularity 2 1 (50.0) 1 (50.0) 0 (0.0) Numbness 1 0 (0.0) 1 (100) 0 (0.0) Table 21: PATIENT DIARY ADVERSE EVENTS - 18 MONTHS Reported Through Patient Diaries Duration By Adverse Event Type N = 100 ADVERSE EVENT TYPE TOTAL REPORTING SYMPTOMS NUMBER OF DAYS 1-3 N (%) 4-7 N (%) 8-14 N (%) > 14 N (%) Ecchymosis 34 11 (32.4) 13 (38.2) 6 (17.6) 4 (11.8) Edema 144 54 (37.5) 74 (51.4) 12 (8.3) 4 (2.8) Erythema 75 51 (68.0) 20 (26.7) 4 (5.3) 0 (0.0) Granuloma 0 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Nodule 0 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Pain 42 18 (42.9) 20 (47.6) 3 (7.1) 1 (2.4) Pruritis 13 11 (84.6) 0 (0.0) 2 (15.4) 0 (0.0) Contour Irregularity 2 0 (0.0) 0 (0.0) 1 (50.0) 1 (50.0) Numbness 2 1 (50.0) 1 (50.0) 0 (0.0) 0 (0.0) Table 22: PHYSICIAN REPORTED ADVERSE EVENTS - 18 MONTHS Maximum Severity By Adverse Event Type N = 100 ADVERSE EVENT TYPE PATIENTS REPORTING SYMPTOMS MILD N (%) MODERATE N (%) SEVERE N (%) Ecchymosis 0 0 (0.0) 0 (0.0) 0 (0.0) Edema 1 1 (100) 0 (0.0) 0 (0.0) Erythema 0 0 (0.0) 0 (0.0) 0 (0.0) Granuloma 0 0 (0.0) 0 (0.0) 0 (0.0) Needle Jamming 0 0 (0.0) 0 (0.0) 0 (0.0) Nodule 0 0 (0.0) 0 (0.0) 0 (0.0) Pain 0 0 (0.0) 0 (0.0) 0 (0.0) Pruritis 0 0 (0.0) 0 (0.0) 0 (0.0) Other 0 0 (0.0) 0 (0.0) 0 (0.0) Table 23: PHYSICIAN REPORTED ADVERSE EVENTS - 18 MONTHS Duration By Adverse Event Type N = 100 ADVERSE EVENT TYPE TOTAL REPORTING SYMPTOMS NUMBER OF DAYS 1-3 N (%) 4-7 N (%) 8-14 N (%) > 14 N (%) Ecchymosis 0 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Edema 1 1 (100) 0 (0.0) 0 (0.0) 0 (0.0) Erythema 0 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Granuloma 0 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Needle Jamming 0 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Nodule 0 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Pain 0 0(0.0) 0(0.0) 0(0.0) 0(0.0) Pruritis 0 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Other 0 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Adverse events reported at 30 months are presented below. Adverse events reported in patient diaries during the 14 days after treatment are listed in Tables 24 and 25. Physician reported adverse events (those reported by Investigators and patients any time outside the 2 week diaries) are presented in Tables 26 and 27. Table 24: PATIENT DIARY ADVERSE EVENTS - 30 MONTHS Reported Through Patient Diaries Maximum Severity By Adverse Event Type N = 100 ADVERSE EVENT TYPE PATIENTS REPORTING SYMPTOMS MILD N (%) MODERATE N (%) SEVERE N (%) Ecchymosis 19 12 (63.2) 7 (36.8) 0 (0.0) Edema 70 43 (61.4) 22 (31.4) 5 (7.1) Erythema 24 18 (75.0) 5 (20.8) 1 (4.2) Granuloma 0 0(0.0) 0(0.0) 0(0.0) Nodule 0 0(0.0) 0(0.0) 0(0.0) Pain 19 11(57.9) 8(42.1) 0(0.0) Pruritis 3 3(100) 0(0.0) 0(0.0) Headache 1 1(100) 0(0.0) 0(0.0) Lump 1 1(100) 0(0.0) 0(0.0) * Other - Miscellaneous 4 3(75.0) 1(25.0) 0(0.0) Numbness 1 0(0.0) 1(100) 0(0.0) Soreness 1 1(100) 0(0.0) 0(0.0) Tightness 1 1 (100) 0 (0.0) 0 (0.0) * 4 patients with the following event types: black eye, nausea, abrasion, pimple. Table 25: PATIENT DIARY ADVERSE EVENTS - 30 MONTHS Reported Through Patient Diaries Duration By Adverse Event Type N = 100 ADVERSE EVENT TYPE TOTAL REPORTING SYMPTOMS NUMBER OF DAYS 1-3 N (%) 4-7 N (%) 8-14 N (%) > 14 N (%) Ecchymosis 34 8 (23.5) 12 (35.3) 10 (29.4) 4 (11.8) Edema 147 57 (38.8) 68 (46.3) 16 (10.9) 6 (4.1) Erythema 49 26 (53.1) 18 (36.7) 3 (6.1) 2 (4.1) Granuloma 0 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Nodule 0 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Pain 34 21 (61.8) 12 (35.3) 1 (2.9) 0 (0.0) Pruritis 5 3 (60.0) 2 (40.0) 0 (0.0) 0 (0.0) Headache 2 0 (0.0) 1 (50.0) 1 (50.0) 0 (0.0) Lump 1 0 (0.0) 1 (100) 0 (0.0) 0 (0.0) * Other - Miscellaneous 5 0 (0.0) 3 (60.0) 1 (20.0) 1 (20.0) Numbness 2 0 (0.0) 0 (0.0) 2 (100) 0 (0.0) Soreness 2 1 (50.0) 1 (50.0) 0 (0.0) 0 (0.0) Tightness 2 0 (0.0) 2 (100) 0 (0.0) 0 (0.0) * 5 reports of the following event types: black eye, nausea, abrasion, pimple. Table 26: PHYSICIAN REPORTED ADVERSE EVENTS - 30 MONTHS Maximum Severity By Adverse Event Type N = 100 ADVERSE EVENT TYPE PATIENTS REPORTING SYMPTOMS MILD N (%) MODERATE N (%) SEVERE N (%) Ecchymosis 1 0 (0.0) 1 (100) 0 (0.0) Edema 6 5 (83.3) 1 (16.7) 0 (0.0) Erythema 0 0 (0.0) 0 (0.0) 0 (0.0) Granuloma 0 0 (0.0) 0 (0.0) 0 (0.0) Needle Jamming 0 0 (0.0) 0 (0.0) 0 (0.0) Nodule 0 0 (0.0) 0 (0.0) 0 (0.0) Pain 0 0 (0.0) 0 (0.0) 0 (0.0) Pruritis 0 0 (0.0) 0 (0.0) 0 (0.0) Other 0 0 (0.0) 0 (0.0) 0 (0.0) Table 27: PHYSICIAN REPORTED ADVERSE EVENTS - 30 MONTHS Duration By Adverse Event Type N = 100 ADVERSE EVENT TYPE TOTAL REPORTING SYMPTOMS NUMBER OF DAYS 1-3 N (%) 4-7 N (%) 8-14 N (%) > 14 N (%) Ecchymosis 2 2 (100) 0 (0.0) 0 (0.0) 0 (0.0) Edema 12 7 (58.3) 4 (33.3) 1 (8.3) 0 (0.0) Erythema 0 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Granuloma 0 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Needle Jamming 0 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Nodule 0 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Pain 0 0(0.0) 0(0.0) 0(0.0) 0(0.0) Pruritis 0 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Other 0 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Clinical Studies Hiv-Associated Facial Lipoatrophy Pre-Market Clinical Trial Study design The safety and effectiveness of RADIESSE injectable implant for the treatment of facial lipoatrophy was evaluated in a prospective, open-label, multi-center study of 100 patients with facial lipoatrophy with human immunodeficiency virus. Patients received an initial treatment (initial injection and an additional injection at 1 month as needed). Six months later, all patients were assessed for the need for a touch up injection. Effectiveness was assessed at 3, 6 and 12 months from initial treatment by means of a Global Aesthetic Improvement Scale (GAIS) rating, cheek skin thickness measurements, and patient satisfaction assessment. Safety was assessed by the recording of adverse events through 12 months. Study Endpoints The primary endpoint of the study was to evaluate the correction of lipoatrophy 3 months after treatment by comparing changes from baseline on the GAIS. The GAIS is a 5-category scale (Very much improved, much improved, improved, no change and worse). The secondary endpoints of the study were to evaluate the correction of facial lipoatrophy 6 months after treatment by comparing changes from baseline on the GAIS, and 3 and 6 months after treatment by comparing changes from baseline in cheek skin thickness measurements. Study Population The inclusion criteria for the clinical study were that the patient was to be HIV positive, had a CD4 count ≥ 250 /mm³ and viral load ≤ 5000 copies/mL, had been receiving HAART therapy for a minimum of 3 years, had HIV-associated facial lipoatrophy that was a grade 2, 3, or 4 on the Facial Lipoatrophy Severity Scale, was at least 18 years of age, signed a written informed consent, understood and accepted the obligation not to receive any other facial procedures or treatment affecting facial lipoatrophy through 12 month follow-up and understood and accepted the obligation and was logistically able to present for all scheduled follow-up visits. The exclusion criteria for the clinical study were patients that had a known bleeding disorder (e.g., thrombocytopenia, thrombasthenia, or von Willebrand's disease), had received or was anticipated to receive antiplatelets, anticoagulants, thrombolytics, vitamin E, anti-inflammatories, interferon, or prednisone from 1 week pre- to 1 month post-injection, was receiving systemic or topical corticosteroids or anabolic steroids, had another medical condition that would preclude study participation or suggested an AIDS diagnosis (e.g., Kaposi sarcoma, recurrent infection, recurrent pneumonia), had received silicone injections, facial tissue augmentation other than collagen, grafting, or any other surgery in the cheek area, had received collagen in the cheek area within the past 6 months, had received over-the-counter wrinkle products (e.g., alphahydroxy acids) or prescription treatments (e.g., Renova, Retin-A, microdermabrasion, chemical peels) within 4 weeks prior to study or intended to receive these products and/or treatments during the study, had facial hair that would preclude ability to assess facial lipoatrophy, had a history of keloid formation, was pregnant or lactating or not using a reliable form of birth control, if female of child bearing potential and was enrolled in an interfering study. Study Results Demographics / Injection Information The study enrolled a population of predominantly multi-ethnic, non-smoking males (94% male) with a mean age of 48 years. Forty-four (44) percent of patients were Black, Hispanic or Asian. Fifty-six (56) percent were Caucasian. Fifty-one (51) percent of patients had a Fitzpatrick Skin score of IV, V or VI. All treatments were performed with a 25 gauge, 1½ inch needle. Mean initial treatment volumes were 4.8mL for the initial treatment and 1.8mL at 1 month if necessary (85% of patients were treated at 1 month). At 6 months, the mean touch up volume was 2.4mL (89% of patients). Four (4) percent of patients received only one treatment, 18% of patients received a total of two treatments and 78% of patients received a total of three treatments. No patient received more than three treatments. Effectiveness Results A live GAIS rating was determined at 3, 6 and 12 months (see Table 28). Table 28: GAIS RATINGS % OF PATIENTS 3 MONTH N = 100 6 MONTH N = 98 12 MONTHS N = 98 Very Much Improved 26% 7% 31% Much Improved 72% 86% 53% Improved 2% 7% 16% No Change 0% 0% 0% Worse 0% 0% 0% TOTAL 100% 100% 100% Cheek thickness measurements of patients left and right cheeks were performed at baseline, 3, 6 and 12 months (see Table 29). Table 29: CHEEK THICKNESS MEASUREMENTS BASELIN E 3 MONTH 6 MONTH 12 MONTH Mean (N=100) Mean (N=100) Δ From Baseline P-Value Mean (N=97) Δ From Baseline P-Value Mean (N=98) Δ From Baseline P-Value Left Cheek 4.7mm 7.3mm 2.6mm < 0.0001 7.1mm 2.4mm < 0.0001 6.9mm 2.2mm < 0.0001 Right Cheek 4.9mm 8.0mm 2.1mm < 0.0001 7.5mm 2.7mm < 0.0001 7.3mm 2.5mm < 0.0001 Patients provided responses to a 5-question patient satisfaction questionnaire at 3, 6 and 12 months (see Table 30). Table 30: PATIENT SATISFACTION ASSESSMENT 3 MONTH N=100 6 MONTH N=98 12 MONTH N = 98 YES YES YES Would you recommend RADIESSE® treatment? 99% 99% 99% Has the RADIESSE® treatment been beneficial to you? 100% 100% 100% Do you feel more attractive since receiving RADIESSE® treatment? 98% 98% 99% Is your emotional wellbeing better since receiving RADIESSE®? 91% 96% 97% Do you have more confidence in your appearance since receiving RADIESSE®? 98% 98% 99% Data For Hiv-Associated Facial Lipoatrophy Long-Term Safety Study Study Objective A post-approval study was performed to evaluate adverse events after repeat injections of RADIESSE injectable implant for the treatment of facial lipoatrophy in patients with human immunodeficiency virus. Study Design The safety and effectiveness of RADIESSE injectable implant for the treatment of facial lipoatrophy was evaluated in a premarket prospective, open-label, multi-center study of 100 patients with facial lipoatrophy with human immunodeficiency virus. As a condition of approval, a post-approval study was undertaken to provide long term data on the patients enrolled in the premarket study to evaluate any adverse events after repeat injections. Effectiveness was assessed as part of the post-approval study at 18 and 30 months from initial treatment by means of a Global Aesthetic Improvement Scale (GAIS) rating, cheek skin thickness measurements, and patient satisfaction assessment. Safety was assessed by the recording of adverse events through 30 months. Touch-up injections were performed as needed at 18 and 30 months. Therefore, the 18-month and 30-month effectiveness results are one year from last touch-up injection. Study Endpoints The primary endpoint of the post-approval study was to evaluate the correction of lipoatrophy 18 and 30 months after treatment by comparing changes from baseline on the GAIS. The GAIS is a 5-category scale (Very much improved, much improved, improved, no change and worse). The secondary endpoint of the post-approval study was to evaluate the correction of facial lipoatrophy 18 and 30 months after treatment by comparing changes from baseline in cheek skin thickness measurements. Study Population The patient cohort in this post approval study was the continued follow-up of the pre-market cohort. The inclusion criterion for the post-approval study was participation in the pre-market clinical study (Section I in HIV-Associated Facial Lipoatrophy CLINICAL STUDIES section) through 12 months, signed a written informed consent, understood and accepted the obligation not to receive any other facial procedures or treatment affecting facial lipoatrophy through 30 month follow-up and understood and accepted the obligation and was logistically able to present for 18 and 30 month follow-up visits. The exclusion criteria for the clinical study were patients that had a known bleeding disorder (e.g., thrombocytopenia, thrombasthenia, or von Willebrand's disease), had received or was anticipated to receive antiplatelets, anticoagulants, thrombolytics, vitamin E, anti-inflammatories, interferon, or prednisone from 1 week pre- to 1 month post-injection, was receiving systemic or topical corticosteroids or anabolic steroids at any time through 30 month visit, had another medical condition that would preclude continued study participation or suggested an AIDS diagnosis (e.g., Kaposi sarcoma, recurrent infection, recurrent pneumonia), intended to receive over-the-counter wrinkle products (e.g., alpha-hydroxy acids) or prescription treatments (e.g., Renova, Retin-A, microdermabrasion, chemical peels) any time through 30 month visit, had a history of keloid formation, was pregnant or lactating or not using a reliable form of birth control, if female of child bearing potential. Follow-up Assessments Patients enrolled in the post-approval study returned for two (2) follow-up assessments after completion of the pre-market study. The first post-approval assessment was 540 ± 45 days from initial treatment if not treated at 1 month and 570 ± 45 days from initial treatment if treated at 1 month (18/19 month visit). The second post-approval assessment was 900 ± 45 days from initial treatment if not treated at 1 month and 930 ± 45 days from initial treatment if treated at 1 month (30/31 month visit). The assessment consisted of a live GAIS rating, facial photographs, skin thickness measurements, patient satisfaction assessment, recording of CD4 counts antiviral loads, recording of relevant medications, and an assessment for adverse events. Study Results The study enrolled a population of predominantly multi-ethnic, non-smoking males (94% male) with a mean age of 48 years (age range of 34 – 69). Forty-four (44) percent of patients were Black, Hispanic or Asian. Fifty-six (56) percent were Caucasian. Fifty-one (51) percent of patients had a Fitzpatrick Skin score of IV, V or VI. All treatments were performed with a 25 gauge, 1½ inch needle. At 18 months, 92% of patients received a mean touch-up volume of 4.4mL. At 30 months, 90% of patients received a mean touch-up volume of 2.8mL. Over the course of both the premarket and post-approval studies, two (2) percent of patients received only one treatment, 3% - two treatments, 5% - 3 treatments, 12% - 4 treatments, and 78% - 5 treatments. No patient received more than five treatments. A live GAIS rating was determined at 18 and 30 months (see Table 31). The last pre-market study touch up injection was allowed at 6 months. Post-market study touch-up injections were allowed at 18 and 30 months. Therefore, the 18-month and 30-month response rates of 91.0% and 90.1%, respectively, are one year from last touch-up injection. Table 31: GAIS RATINGS RATING 18 MONTHS N = 94 30 MONTHS N = 91 Very Much Improved 9.6% 3.3% Much Improved 43.6% 28.6% Improved 38.3% 58.2% No Change 8.5% 8.8% Worse 0.0% 1.1% TOTAL IMPROVED 91.0% 90.1% Cheek thickness measurements of patients left and right cheeks were performed at 18 and 30 months and are one year from last touch up injection (see Table 32). Table 32: CHEEK THICKNESS MEASUREMENTS MEAN BASELINE N=100 18 MONTHS N = 93 30 MONTHS N = 91 mm mm ΔFrom Baseline p-value mm Δ From Baseline p-value Left Side 4.7 6.2 1.45 < 0.0001 6.8 2.1 < 0.0001 Right Side 4.9 6.5 1.71 < 0.0001 7.2 2.3 < 0.0001 Patients provided responses to a 5-question patient satisfaction questionnaire at 18 and 30 months, one year from last touch up injection (see Table 33). Table 33: PATIENT SATISFACTION ASSESSMENT QUESTIONS % ANSWERING “YES” 18 MONTHS N=94 30 MONTHS N=91 Would you recommend RADIESSE® treatment? 98.9% 100% Has the RADIESSE® treatment been beneficial to you? 98.9% 100% Do you feel more attractive since receiving RADIESSE® treatment? 97.9% 100% Is your emotional wellbeing better since receiving RADIESSE®? 94.7% 95.6% Do you have more confidence in your appearance since receiving RADIESSE®? 98.9% 100% Study Limitations RADIESSE injectable implant was studied in a limited number of predominately male HIV positive patients. The safety of RADIESSE injectable implant following treatment of HIV associated Lipoatrophy beyond 30 months was not studied. Other Short Term And Long Term Radiographic Evaluation RADIESSE injectable implant contains calcium hydroxylapatite particles (25-45 microns) that are radiopaque and suspended in a water based gel. Therefore a radiographic study was conducted to assess the radiographic appearance of RADIESSE injectable implant in patients with both short-term and long-term follow-up after injection for HIV-associated facial lipoatrophy and treatment of nasolabial folds. The radiographic assessment consisted of standard, plain radiography and CT scanning. X-rays and CT Scans were assessed by two blinded, licensed radiologists. The inclusion of these patients allowed assessment of patients immediately after initial injection, at least 12 months after initial injection, and patients with varying volumes implanted. A total of 58 patients in three patients groups were enrolled into the study. RADIESSE injectable implant was determined to be visualizable in the X-ray radiographs by both evaluators, but the X-ray readings were not conclusive for the presence of the implant, when in fact it was present. This may be due to the fact that the volume of RADIESSE injectable implant in some patients was small and the sensitivity of X-ray imaging may not be sufficient to detect small volumes of implant. RADIESSE injectable implant was more readily visualizable by CT Scan when compared to X-ray and the CT Scan results were read more consistently between two evaluators. RADIESSE injectable implant was easily seen when imaging was done soon after an injection and was also seen when imaging was done several months after injection (minimum of 12 months). As expected, the results for the CT Scan provided a superior image capability as compared to X-ray when visualizing RADIESSE injectable implant.

Drug Description

RADIESSE® (calcium hydroxylapatite particle in an aqueous gel carrier) Volumizing Filler for Wrinkle Reduction DESCRIPTION RADIESSE® injectable implant is a sterile, non-pyrogenic, semi-solid, cohesive implant, whose principle component is synthetic calcium hydroxylapatite suspended in a gel carrier of sterile water for injection, glycerin and sodium carboxymethylcellulose. RADIESSE injectable implant (3.0cc, 1.5cc, 0.8cc, 0.3cc) has a CaHA particle size range of 25–45 microns and should be injected with a 25 gauge Outer Diameter (O.D.) to 27 gauge Inner Diameter (I.D.) needle.

Indications & Dosage

INDICATIONS RADIESSE injectable implant is indicated for subdermal implantation for the correction of moderate to severe facial wrinkles and folds, such as nasolabial folds and it is also intended for restoration and/or correction of the signs of facial fat loss (lipoatrophy) in people with human immunodeficiency virus. DOSAGE AND ADMINISTRATION Directions For Use General The following is required for the percutaneous injection procedure: RADIESSE injectable implant syringe(s) 25 gauge OD - 27 gauge ID needle(s) with Luer lock fittings Prepare patient for percutaneous injection using standard methods. The treatment injection site should be marked and prepared with a suitable antiseptic. Local or topical anesthesia at the injection site should be used at the discretion of the physician. Prepare the syringes of RADIESSE injectable implant and the injection needle(s) before the percutaneous injection. A new injection needle may be used for each syringe, or the same injection needle may be connected to each new syringe. Remove foil pouch from the carton. Open the foil pouch by tearing at the notches (marked 1 and 2), and remove the syringe from the foil pouch. There is a small amount of moisture normally present inside the foil pouch for sterilization purposes; this is not an indication of a defective product. Peel or twist apart the needle packaging to expose the hub. For use of needles other than the needle(s) provided with this package, follow the directions provided with the needle(s). Remove the Luer syringe cap from the distal end of the syringe prior to attaching the needle. The syringe of RADIESSE injectable implant can then be twisted onto the Luer lock fitting of the needle taking care not to contaminate the needle. Discard needle package. The needle must be tightened securely to the syringe and primed with RADIESSE injectable implant. If excess implant is on the surface of the Luer lock fittings, it will need to be wiped clean with sterile gauze. Slowly push the syringe plunger until RADIESSE injectable implant extrudes from the end of the needle. If leakage is noted at the Luer fitting, it may be necessary to tighten the needle, or to remove the needle and clean the surfaces of the Luer fitting or, in extreme cases, replace both the syringe and the needle. Locate the initial site for the implant. Scar tissue and cartilage may be difficult or impossible to treat. Avoid if possible, passing through these tissue types when advancing the injection needle. The amount injected will vary depending on the site and extent of the restoration or augmentation desired. RADIESSE injectable implant should be injected subdermally. Use a 1:1 correction factor. No overcorrection is needed. Insert needle with bevel down at approximately a 30° angle to the skin. Needle should slide under the dermis to the point you wish to begin the injection. This should be easily palpable with the non-dominant hand. If significant resistance is encountered when pushing the plunger, the injection needle may be moved slightly to allow easier placement of the material or it may be necessary to change the injection needle. One needle jam occurred in the nasolabial fold clinical study. Needle jams are more likely with use of needles smaller than 27gauge ID. Advance the needle into the subdermis to the starting location. Carefully push the plunger of the RADIESSE injectable implant syringe to start the injection and slowly inject the implant material in linear threads while withdrawing the needle. Continue placing additional lines of material until the desired level of correction is achieved. Apply slow continuous even pressure to the syringe plunger to inject the implant as you withdraw the needle. The implant material should be completely surrounded by soft tissue without leaving globular deposits. The injected area may be massaged as needed to achieve even distribution of the implant. Use once and discard in accordance with local safety standards. Technique for Mixing RADIESSE injectable implant and 2% Lidocaine HCl CAUTION: Do not use the RADIESSE injectable implant and 2% lidocaine mixture later than 2 hours after mixing. CAUTION: The assembled components are intended for one-time use only. Within the clinical study, the following components were used: Sterile 27 gauge, 0.5” regular-wall needle with Luer lock connector (not supplied by Merz Aesthetics, Inc.). 3.0cc sterile polypropylene luer-lock syringe (BD 309585) 0.2cc of Hospira, Inc. (NDC 0409-4277-02) 2% lidocaine HCl for injection, USP solution (not supplied by Merz Aesthetics, Inc.) Sterile Female-to-female luer lock connector (Braun FDC1000 or Baxa 13901) 1.3cc syringe of RADIESSE injectable implant The 3.0cc sterile polypropylene mixing syringe (BD 309585) and the female-to-female luer lock connector (Baxa 13901) are separately available in the Merz Aesthetics Accessory Kit. Neither the lidocaine nor the sterile 27 gauge, 0.5“ needle are supplied by Merz Aesthetics, Inc. Component Assembly and Mixing Instructions 1. Assemble the components and perform the mixing using sterile technique (see Figure 1). Figure 1: Left to right: Female-to-female luer lock connector, RADIESSE syringe, 3.0cc mixing syringe, sterile 27 gauge, 0.5” needle 2. Draw the lidocaine into a 3.0cc sterile polypropylene mixing syringe fitted with a sterile 27 gauge, 0.5” needle. 3. Tap the mixing syringe, containing lidocaine and depress its push rod to remove all excess air. 4. Remove the sterile 27gauge, 0.5” needle. 5. Firmly connect the mixing syringe to the RADIESSE syringe using the female-to-female luer lock connector (see Figures 2 and 3). Figure 2 Figure 3 6. Mix the lidocaine and RADIESSE injectable implant by alternately depressing the plungers, first on the mixing syringe and then on the RADIESSE syringe for ten mixing strokes (each mixing stroke is one complete compression of the mixing syringe plunger followed by one complete compression of the RADIESSE syringe plunger). Plungers are compressed firmly and quickly, at about two compressions per second. Figure 4 7. After mixing, remove the mixing syringe and the female-to-female luer lock connector and discard. 8. Fit the syringe containing the lidocaine and RADIESSE mixture with an injection needle. 9. Proceed with the injection of the RADIESSE injectable implant. The clinical study was conducted by mixing 0.2cc of 2% lidocaine with 1.3cc of RADIESSE injectable implant in the 3.0cc BD syringe. The table below provides the ratio of 2% lidocaine to be mixed with the various syringe volumes of RADIESSE injectable implant. These ratios result in the same concentration of 2% lidocaine (w/v%) in RADIESSE injectable implant that was mixed in the clinical study after accounting for the dead space in the RADIESSE and 3.0cc BD mixing syringes (see Table 34). Table 34: LIDOCAINE CONCENTRATION RADIESSE® (cc) 2% Lidocaine (cc) Resulting Lidocaine Concentration (w/v%) 0.3 0.02 0.30% - 0.33% 0.8 0.11 0.31% - 0.32% 1.3 0.20 0.31% - 0.32% 1.5 0.26 0.31% - 0.32% 3.0 0.45 0.32% - 0.34% Storage RADIESSE injectable implant should be stored at a controlled room temperature between 15° C and 32° C (59° F and 90° F). The expiration date, when stored in these temperatures, is two years from date of manufacture. Do not use if the expiration date has been exceeded. Disposal Used and partially used syringes and injection needles could be biohazardous and should be handled and disposed of in accordance with facility medical practices and local, state or federal regulations. Warranty Merz Aesthetics, Inc. warrants that reasonable care has been exercised in the design and manufacture of this product. THIS WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES NOT EXPRESSLY SET FORTH HEREIN, WHETHER EXPRESSED OR IMPLIED BY OPERATION OF LAW OR OTHERWISE, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ITS PARTICULAR PURPOSE. Handling and storage of this product, as well as factors relating to the patient, diagnosis, treatment, surgical procedures and other matters beyond Merz Aesthetics's control directly affect the product and the results obtained from its use. Merz Aesthetics's obligation under this warranty is limited to the replacement of this product and Merz Aesthetics shall not be liable for any incidental or consequential loss, damage, or expense, directly or indirectly, arising from the use of this product. Merz Aesthetics neither assumes, nor authorizes any person to assume for Merz Aesthetics, any other or additional liability or responsibility in connection with this product. Manufactured by: Merz Aesthetics, Inc., 4133 Courtney Road, Suite #10, Franksville, WI 53126 U.S.A. Fax: 262-835-3330

Medication Guide

PATIENT INFORMATION RADIESSE® Dermal Filler for the Correction of Moderate to Severe Facial Wrinkles and Folds, Such As Nasolabial Folds Read all the information before you are treated with Radiesse® dermal filler. Keep this information. You may want to refer to it again. If you have any questions, please ask your doctor. Introduction This information will help you decide whether treatment with RADIESSE dermal filler is right for you. This information does not take the place of a discussion with your doctor but will answer some questions about RADIESSE dermal filler treatment. Please read this information and discuss any questions with your doctor. Only you and your doctor can decide whether RADIESSE dermal filler is right for you. GLOSSARY Anesthetic A substance that causes temporary loss of feeling that may make your dermal filler treatment more comfortable. Calcium Hydroxylapatite A substance compatible with living systems that dissolves in the body that is identical in composition to the mineral portion of teeth and bone. Granuloma A small area of swelling (inflammation) around the dermal filler material due to the body's response to the material. Nodule: A small lump of dermal filler material. Side effect: An undesirable event caused by use of the dermal filler. Background information What is RADIESSE dermal filler ? RADIESSE dermal filler is an injectable for facial folds and wrinkles. Calcium Hydroxylapatite has a history of safe use in otology (ears), laryngeal (vocal chords), and dental and orthopedic applications (see glossary). What is RADIESSE dermal filler used for ? RADIESSE dermal filler is used to fill moderate to severe facial wrinkles and folds, such as nasolabial folds—the creases that extend from the corner of your nose to the corner of your mouth. RADIESSE dermal filler will not correct the underlying causes. Can RADIESSE dermal filler work for me? Talk to your doctor about your medical history when deciding on treatment options. You should not use RADIESSE dermal filler if you are allergic to any of its ingredients. You should also not choose RADIESSE dermal filler if you desire only short-term results. How does RADIESSE dermal filler work? Once injected, RADIESSE dermal filler immediately adds fullness to your face giving you a visible result at the first treatment session. RADIESSE dermal filler contains microspheres made of a natural material called Calcium Hydroxylapatite in a water based gel carrier. How long do treatment effects last ? Although treatment effects will differ for each person, in a clinical study, RADIESSE dermal filler lasted up to 6 months according to independent doctors in a blinded test. The people in this study were followed after the clinical study and the unblinded treating doctor rated some people still improved up to two years from RADIESSE dermal filler treatment. Do injections of RADIESSE dermal filler hurt ? As with any injection, injections with RADIESSE dermal filler may hurt. RADIESSE dermal filler is injected in small amounts using a very fine needle. Your doctor may apply a topical or local anesthetic. Are skin tests needed before treatment with RADIESSE dermal filler ? No skin testing is required prior to use. Should I tell my healthcare provider what medicatio ns I am taking? Yes. You should tell your doctor about all the medicines you are taking, even over the counter medicines or treatments. If you are taking blood thinners or medications that may interfere with clotting of the blood, such as aspirin, you might be more likely to have bruising or bleeding at the injection site. There have been no studies of possible interactions between RADIESSE dermal filler and drugs or other substances or implants. What can I expect to happen at a treatment session? Your doctor will answer all of your questions and prepare you for the treatment. The area where the injections will be given will be cleaned with an antiseptic. You and your doctor will determine if a topical or local anesthetic is needed. RADIESSE dermal filler will be injected in small amounts into the skin using a very fine needle. An ice pack may be applied to the treatment area before or after treatment to help reduce swelling. What are the possible side effects of treatment with RADIESSE dermal filler ? Talk to your doctor about the possible side effects of RADIESSE dermal filler. The most common side effects are redness, bruising, or swelling. These side effects generally last for a short time and are mild in nature. As with all procedures that involve an injection through the skin, there is a risk of infection. However, no infections have been reported in the clinical study of RADIESSE dermal filler. Report any side effects you may experience to your doctor. The table below shows the types of side effects reported in a clinical study of 117 patients with RADIESSE dermal filler and another similar product (Tables 1 – 4). Long term side effects were studied in 102 patients and no long term side effects were observed through out the 3 years of follow-up. Table 1: Side Effects Reported Through Patient Diaries RADIESSE TOTAL N (%) CONTROL TOTAL N (%) BRUISING 74 (63.2) 50 (42.7) SWELLING 81 (69.2) 62 (53.0) REDNESS 78 (66.7) 84 (71.8) GRANULOMA 0(0.0) 0(0.0) NODULE 1 (0.9) 1 (0.9) PAIN 33 (28.2) 26 (22.2) ITCHING 21 (18.0) 24 (20.5) OTHER 35 (29.9) 26 (22.2) Table 2: Side Effects Reported Through Other Methods RADIESSE TOTAL N (%) CONTROL TOTAL N (%) BRUISING 0 (0.0) 2 (1.7) SWELLING 5 (4.3) 4(3.4) REDNESS 6 (5.1) 9 (7.7) GRANULOMA 0 (0.0) 0 (0.0) NEEDLE JAMMING 1 (0.9) 0 (0.0) NODULE 0 (0.0) 2 (1.7) PAIN 2 (1.7) 1 (0.9) ITCHING 1 (0.9) 2 (1.7) OTHER 3 (2.6) 3(2.6) Table 3: Length of time for Side Effects Reported Through Patient Diaries RADIESSE CONTROL RADIESSE CONTROL TOTAL REPORTING SYMPTOMS N (%) TOTAL REPORTING SYMPTOMS N (%) NUMBER OF DAYS NUMBER OF DAYS 1-3 N (%) 4-7 N (%) 8-14 N (%) > 14 N (%) 1-3 N (%) 4-7 N (%) 8-14 N (%) > 14 N (%) BRUISING 91 (60.3) 60 (39.7) 16 (10.6) 37 (24.5) 33 (21.9) 5 (3.3) 15 (9.9) 29 (19.2) 12 (7.9) 4 (2.6) SWELLING 104 (54.5) 87 (45.5) 34 (17.8) 43 (22.5) 17 (8.9) 10 (5.2) 34 (17.8) 39 (20.4) 10 (5.2) 4 (2.1) REDNESS 105 (45.1) 9) 39 (16.7) 26 (11.2) 19 (8.2) 21 (9.0) 45 (19.3) 35 (15.0) 16 (6.9) 32 (13.7) GRANULOMA 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) NODULE 1 (50.0) 1 (50.0) 0 (0.0) 0 (0.0) 0 (0.0) 1 (50.0) 0 (0.0) 0 (0.0) 0 (0.0) 1 (50.0) PAIN 40 (54.8) 33 (45.2) 22 (30.1) 13 (17.8) 4 (5.5) 1 (1.4) 20 (27.4) 10 (13.7) 2 (2.7) 1 (1.4) ITCHING 24 (47.1) 27 (52.9) 15 (29.4) 5 (9.8) 3 (5.9) 1 (2.0) 11 (21.6) 10 (19.6) 3 (5.9) 3 (5.9) OTHER 52 (56.5) 40 (43.5) 15 (16.3) 17 (18.5) 8 (8.7) 12 (13.0) 8 (8.7) 10 (10.9) 11 (12.0) 11 (12.0) Table 4: Length of time for Side Effects Reported Through Other Methods RADIESSE CONTROL RADIESSE CONTROL TOTAL SYMPTOMS N (%) TOTAL SYMPTOMS N (%) NUMBER OF DAYS NUMBER OF DAYS 1-3 N (%) 4-7 N (%) 8-14 N (%) > 14 N (%) 1-3 N (%) 4-7 N (%) 8-14 N (%) > 14 N (%) BRUISING 0 (0.0) 2 (100.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 1 (50.0) 1 (50.0) 0 (0.0) SWELLING 5 (41.7) 7 (58.3) 5 (41.7) 0 (0.0) 0 (0.0) 0 (0.0) 5 (41.7) 0 (0.0) 0 (0.0) 2 (16.7) REDNESS 9 (42.9) 12 (57.1) 4 (19.0) 2 (9.5) 2 (9.5) 1 (4.8) 2 (9.5) 3 (14.3) 4 (19.0) 3 (14.3) GRANULOMA 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) NEEDLE JAMMING 1 (100.0) 0 (0.0) 1 (100.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) NODULE 0 (0.0) 3 (100.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 1 (33.3) 2 (66.7) PAIN 3 (75.0) 1 (25.0) 1 (25.0) 1 (25.0) 0 (0.0) 1 (25.0) 1 (25.0) 0 (0.0) 0 (0.0) 0 (0.0) ITCHING 1 (33.3) 2 (66.7) 0 (0.0) 0 (0.0) 1 (33.3) 0 (0.0) 1 (33.3) 0 (0.0) 1 (33.3) 0 (0.0) OTHER 4 (50.0) 4 (50.0) 1 (12.5) 0 (0.0) 2 (25.0) 1 (12.5) 1 (12.5) 1 (12.5) 0 (0.0) 2 (25.0) What can I expect after treatment? Immediately following a treatment session with RADIESSE dermal filler redness, bruising or swelling may occur in the treatment area. These signs usually go away in a short period and are generally mild in nature. An ice pack may be applied to the treatment area to help reduce swelling. Your health care provider will give you specific post-treatment care instructions. For approximately 24 hours after treatment: Avoid significant movement or massage of the treated area. Do not apply makeup. Avoid extensive sun or heat exposure. After you leave the office, you may experience redness, bruising or swelling for a few days. Not all patients experience these, but please note that such effects can occur and are not out of the ordinary for such a treatment. You may be able to feel the area where RADIESSE dermal filler was injected for some period after injection. Over time, the injected area will feel more and more like your own tissue. How quickly can I get back to my daily activities ? Most patients feel comfortable going back to their normal activities immediately after treatment with RADIESSE dermal filler. How many treatments are required ? Your doctor will decide with you the number of treatment sessions and the amount of RADIESSE dermal filler you will need at each treatment session.  Generally, significant changes may be achieved in a first treatment. A touch-up may be required to achieve optimal results. Without touch-up injections, how will my skin look? Your skin will begin to gradually look like it did before treatment as you near the end of the time period RADIESSE dermal filler usually lasts. Periodic touch up injections will help you maintain the look you have after treatment. What other things do I need to know ? The Microspheres in RADIESSE dermal filler can be seen in X-rays and CT Scans. It is very important that you inform your doctor and other health care professionals that you have RADIESSE dermal filler injected in your face. Even though RADIESSE dermal filler can be seen in X-rays and CT Scans, there is not a high risk that it would cause your doctor concern, as long as s/he knows that you have had RADIESSE dermal filler injected in your face. QUESTIONS FOR MY DOCTOR _________________________________ _________________________________ _________________________________

Overdosage & Contraindications

Side Effects & Drug Interactions

SIDE EFFECTS Adverse Events Nasolabial folds pre-market clinical trial Tables 1-4 contain the adverse events for 117 patients in a randomized, controlled study at 4 US investigational sites. Patients in the study received RADIESSE injectable implant in one side of the face and a collagen dermal implant as the Control in the other side of the face. Adverse events reported in patient diaries during the 14 days after treatment are listed in Tables 1 and 2. Physician reported adverse events are those reported by Investigators and patients any time outside the 2 week diaries. Those adverse events are presented in Tables 3 and 4. Table 1:  PATIENT DIARY ADVERSE EVENTS Reported Through Patient Diaries Number of Patients With at Least One Adverse Event By Adverse Event Type N = 117 ADVERSE EVENT TYPE RADIESSE® Total Reporting Symptoms N (%) CONTROL Total Reporting Symptoms N (%) Ecchymosis 74 (63.2) 50 (42.7) Edema 81(69.2) 62(53.0) Erythema 78 (66.7) 84 (71.8) Granuloma 0(0.0) 0(0.0) Nodule 1(0.9) 1(0.9) Pain 33(28.2) 26(22.2) Pruritis 21 (18.0) 24 (20.5) Other* 35 (29.9) 26 (22.2) * “Other” adverse events for both RADIESSE injectable implant and Control include soreness, numbness, contour irregularity, tenderness, and irritation. None of the reports of contour irregularities was determined to be nodules or granulomas. There were 12 systemic adverse events reported for 9 patients. None of these systemic adverse events were related to either RADIESSE injectable implant or Control and included emergency gallbladder surgery, breast pain, infected and exposed breast implant, gastroenteritis, uterine fibroids, headache, burning and numbness in tongue and lips, tongue ulceration and fatigue. Table 2: PATIENT DIARY ADVERSE EVENTS By Adverse Event Type N = 117 ADVERSE EVENT TYPE RADIESSE® CONTROL RADIESSE® CONTROL Total Reporting Symptoms Total Reporting Symptoms Number of Days Number of Days N (%) N (%) 1-3 N (%) 4-7 N (%) 8-14 N (%) > 14 N (%) 1-3 N (%) 4-7 N (%) 8-14 N (%) > 14 N (%) Ecchymosis 91 (60.3) 60 (39.7) 16 (10.6) 37 (24.5) 33 (21.9) 5 (3.3) 15 (9.9) 29 (19.2) 12 (7.9) 4(2.6) Edema 104(54.5) 87(45.5) 34(17.8) 43(22.5) 17(8.9) 10(5.2) 34(17.8) 39(20.4) 10(5.2) 4(2.1) Erythema 105(45.1) 128(54.9) 39(16.7) 26(11.2) 19(8.2) 21(9.0) 45(19.3) 35(15.0) 16(6.9) 32(13.7) Granuloma 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Nodule 1 (50.0) 1 (50.0) 0 (0.0) 0 (0.0) 0 (0.0) 1 (50.0) 0 (0.0) 0 (0.0) 0 (0.0) 1 (50.0) Pain 40(54.8) 33(45.2) 22(30.1) 13(17.8) 4(5.5) 1(1.4) 20(27.4) 10(13.7) 2(2.7) 1(1.4) Pruritis 24(47.1) 27(52.9) 15(29.4) 5(9.8) 3(5.9) 1(2.0) 11(21.6) 10(19.6) 3(5.9) 3(5.9) Other* 52(56.5) 40(43.5) 15(16.3) 7(18.5) 8(8.7) 12(13.0) 8(8.7) 10(10.9) 11(12.0) 11(12.0) * “Other” adverse events for both RADIESSE injectable implant and Control include soreness, numbness, contour irregularity, tenderness, and irritation. None of the reports of contour irregularities was determined to be nodules or granulomas. Table 3: PHYSICIAN REPORTED ADVERSE EVENTS Number of Patients With at Least One Adverse Event By Adverse Event Type N = 117 ADVERSE EVENT TYPE RADIESSE® Total Reporting Symptoms N (%) CONTROL Total Reporting Symptoms N (%) Ecchymosis 0 (0.0) 2 (1.7) Edema 5 (4.3) 4 (3.4) Erythema 6 (5.1) 9 (7.7) Granuloma 0 (0.0) 0 (0.0) Needle Jamming 1 (0.9) 0 (0.0) Nodule 0 (0.0) 2 (1.7) Pain 2 (1.7) 1 (0.9) Pruritis 1 (0.9) 2 (1.7) Other* 3 (2.6) 3 (2.6) * “Other” adverse events for both RADIESSE injectable implant and Control include soreness, numbness, contour irregularity, tenderness, and irritation. None of the reports of contour irregularities was determined to be nodules or granulomas. Table 4: PHYSICIAN REPORTED ADVERSE EVENTS By Adverse Event Type N = 117 ADVERSE EVENT TYPE RADIESSE® Total Reporting Symptoms N (%) CONTROL Total Reporting Symptoms N (%) RADIESSE® CONTROL 1-3 N (%) Number of Days 4-7 N (%) 8-14 N (%) > 14 N (%) 1-3 N (%) Number of Days 4-7 N (%) 8-14 N (%) > 14 N (%) Ecchymosis 0 (0.0) 2 (100.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 1 (50.0) 1 (50.0) 0 (0.0) Edema 5 (41.7) 7 (58.3) 5 (41.7) 0 (0.0) 0 (0.0) 0 (0.0) 5 (41.7) 0 (0.0) 0 (0.0) 2 (16.7) Erythema 9 (42.9) 12 (57.1) 4 (19.0) 2 (9.5) 2 (9.5) 1 (4.8) (9 3 (14.3) 4 (19.0) 3 (14.3) Granuloma 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) Needle 1 0 1 0 0 0 0 0 0 0 Jamminq (100.0) (0.0) (100.0) (0.0) (0.0) (0.0) (0.0) (0.0) (0.0) (0.0) Nodule 0 (0.0) 3 (100.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 1 (33.3) 2 (66.7) Pain 3 1 1 1 0 1 1 0 0 0 (75.0) (25.0) (25.0) (25.0) (0.0) (25.0) (25.0) (0.0) (0.0) (0.0) Pruritis 1 (33.3) 2 (66.7) 0 (0.0) 0 (0.0) 1 (33.3) 0 (0.0) 1 (33.3) 0 (0.0) 1 (33.3) 0 (0.0) Other* 4 (50.0) 4 (50.0) 1 (12.5) 0 (0.0) 2 (25.0) 1 (12.5) 1 (12.5) 1 (12.5) 0 (0.0) 2 (25.0) * “Other” adverse events for both RADIESSE injectable implant and Control include soreness, numbness, contour irregularity, tenderness, and irritation. None of the reports of contour irregularities was determined to be nodules or granulomas. Nasolabial Folds Mixing Radiesse Injectable Implant With 2% Lidocaine Hcl Pre-Market Clinical Trial In a prospective, randomized split-face single-blind clinical study, 50 patients were injected with syringes of 1.3cc of RADIESSE injectable implant mixed with 0.2cc of 2% lidocaine HCl (lidocaine) in one nasolabial fold (Treatment) and RADIESSE injectable implant without the 2% lidocaine (Control) in the contralateral nasolabial fold at two investigational sites in the United States. The purpose of this study was to assess the effectiveness of RADIESSE injectable implant mixed with 2% lidocaine for the reduction of pain during injection and the incidence of adverse events through the 1 month follow-up period. The adverse events reported during this study were generally expected, mild in nature and short in duration and are detailed in the tables below. Adverse events were reported through patient diaries and by the principal investigators, with the majority of adverse events reported through the patient diaries. Adverse events are presented by time point and in total for the Treatment and Control groups. The majority of adverse events were reported in the ≤ 14 day time period. There was no statistical difference with respect to occurrence of patient diary reported adverse events between the 2 groups (see Table 5). There were 2 adverse events reported by the investigators (depression for one patient and redness for one patient in the Control nasolabial fold). Table 5: ADVERSE EVENTS REPORTED IN PATIENT DIARIES N = 50 ADVERSE EVENT TYPE NUMBER OF ADVERSE EVENTS REPORTED ≤ 14 DAYS > 14 DAYS TOTAL TREATMENT CONTROL TREATMENT CONTROL TREATMENT CONTROL p-value Bruising 26 25 0 0 26 25 1.0000 Itching 11 12 2 4 13 16 0.1573 Pain 22 25 0 0 22 25 0.5271 Redness 29 32 0 0 29 32 0.4795 Swelling 47 44 0 0 47 44 0.4795 Other* 5 4 1 2 6 6 N/A * “Other” adverse events for both Treatment & Control include bleeding, small bump, numbness, needle marks, nostril sensitivity & skin tightness. Nasolabial Folds Long-Term Safety Post-Approval Study A post approval study was performed to 1) collect long-term safety information on use of RADIESSE injectable implant injected into the nasolabial folds; and 2) to assess the effect of multiple injections. There were no reports of long term adverse events in this post approval study. The adverse events monitored in the post-approval study included allergic reaction, ecchymosis, edema, embolization, erosion, erythema, extrusion, granuloma, hematoma, infection, necrosis, needle jamming, nodule, and pain. Nasolabial Folds Fitzpatrick Skin Type Iv-Vi Post-Approval Study Adverse events reported in the short-term Fitzpatrick Skin Type IV-VI post-approval study are presented in Table 6. Table 6: ADVERSE EVENTS N = 100 ADVERSE EVENT TYPE PATIENTS REPORTING SYMPTOMS N (%) Hypertrophic Scarring 0 (0.0) Keloid Formation 0 (0.0) Hypopigmentation 0 (0.0) Hyperpigmentation-Upper Lip 1 (1.0) Hyperpigmentation-Other 0 (0.0) Bumpiness 1 (1.0) Ecchymosis 7 (7.0) Eczema on Leg 1 (1.0) Edema 12 (12.0) Erythema 16 (16.0) Eye Stye 1 (1.0) Mild Bleeding at Injection Site 1 (1.0) Needle Jamming 1 (1.0) Tenderness 2 (2.0) Urinary Tract Infection 1 (1.0) Post Marketing Surveillance The following adverse events were received from post-marketing surveillance for the RADIESSE injectable implant in the US and outside the US and were not observed in the clinical trials with RADIESSE injectable implant: infection, over-injection, under-injection, loss of effect, product displacement, allergic reaction, necrosis, granuloma, exposed material, hair loss, tingling, ptosis, abscess, paralysis, superficial injection, herpetic infection, hematoma, blanching, blistering, bluish color, dark circles, did not like results, dizziness, double vision, festoons, flu-like symptoms, grey discoloration, Guillain-Barre syndrome, hyperventilating, inflammation, ischemic reaction, lymphoid hyperplasia, nausea, pallor to skin, prior medical condition worsened, pericarditis, possible blood clot, scarring, sensitivity to cold, skin texture changed, tissue mass developed, vascular compromise, and ocular ischemia. The most commonly reported serious adverse events (with a frequency greater than 5 reported events) were necrosis, allergic reaction, edema, and infection. The following describes these serious adverse events: Necrosis was generally preceded by pain and blanching of the skin at the time of injection accompanied with stinging or tingling and bruising, redness, and swelling. Onset of necrosis ranged from immediately at time of injection to 12 days after injection. Treatment for necrosis generally consisted of a combination of nitroglycerin ointment/vasodilatation, ibuprofen, acetaminophen, or aspirin, antibiotics, steroids, non-steroidal wound treatment ointment and warm compresses. For cases where information was available, patients had recovered or were recovering with minimal to no scarring at last contact. Few cases required consultation with a plastic surgeon and possible excision and revision surgery to correct the defect resulting from the necrosis. Allergic Reaction was identified by itchiness and severe swelling, including swelling of the face and tongue. Onset ranged from immediately after injection to 2 days after injection. Allergic reaction was generally treated with anti-histamines and steroids. Some cases required hospitalization. All patients recovered from the allergic reaction with no permanent adverse outcome. Serious edema has been reported with an onset ranging from 1 day to 3 weeks (inflammation related to nodule formation). Treatment generally consisted of administration of antibiotics, anti-histamines and steroids. In some cases patients sought treatment in an emergency room or were hospitalized. Generally events resolved within 1 to 2 days but a few patients have been reported as having intermittent edema or persistent edema related to a reoccurring infection. For cases where information was available, most patients have recovered or are recovering. Infection, often identified as cellulitis, was accompanied by swelling, hardened areas, redness, pustules, and pain. Onset of infection ranged from 1 day to 2 months and generally lasted 2 days but, in one case, persisted for 6 months. Infections were generally treated with antibiotics. For cases where information was available, patients had recovered or were recovering. Few patients experienced scarring that may require corrective surgery or discoloration at the site of the infection. Individualization Of Treatment Before treatment, the patient's suitability for the treatment and the patient's need for pain relief should be assessed. The outcome of treatment with RADIESSE injectable implant will vary between patients. In some instances, additional treatments may be necessary depending on the size of the defect and the needs of the patient. DRUG INTERACTIONS No information provided.

Warnings & Precautions

WARNINGS Use of RADIESSE injectable implant in any person with active skin inflammation or infection in or near the treatment area should be deferred until the inflammatory or infectious process has been controlled. Injection procedure reactions have been observed consisting mainly of short-term (i.e., < 7 days) bruising, redness and swelling. Refer to adverse events sections for details. Special care should be taken to avoid injection into the blood vessels. An introduction into the vasculature may occlude the vessels and could cause infarction or embolism leading to ischemia, necrosis or scarring. This has been reported to occur in the lips, nose, glabellar or ocular area. Do not overcorrect (overfill) a contour deficiency because the depression should gradually improve within several weeks as the treatment effect of RADIESSE injectable implant occurs. The safety and effectiveness for use in the lips has not been established. There have been published reports of nodules associated with the use of RADIESSE injectable implant injected into the lips. PRECAUTIONS The calcium hydroxylapatite (CaHA) particles of RADIESSE injectable implant are radiopaque and are clearly visible on CT Scans and may be visible in standard, plain radiography. Patients need to be informed of the radiopaque nature of RADIESSE injectable implant, so that they can inform their primary care health professionals as well as radiologists. In a radiographic study of 58 patients, there was no indication of RADIESSE injectable implant potentially masking abnormal tissues or being interpreted as tumors in CT  Scans. Only health care providers with expertise in the correction of volume deficiencies in patients with human immunodeficiency virus should treat such patients with RADIESSE injectable implant after fully familiarizing themselves with the product, the product educational materials and the entire package insert. Packaged for single patient use. Do not resterilize. Do not use if package is opened or damaged. Do not use if the syringe end cap or syringe plunger is not in place. Safety of RADIESSE injectable implant beyond 3 years has not been investigated in clinical trials. The safety of RADIESSE injectable implant in patients with increased susceptibility to keloid formation and hypertrophic scarring has not been studied. As with all transcutaneous procedures, RADIESSE injectable implant injection carries a risk of infection. Standard precautions associated with injectable materials should be followed. Safety of RADIESSE injectable implant for use during pregnancy, in breastfeeding females or in patients under 18 years has not been established. Patients who are using medications that can prolong bleeding, such as aspirin or warfarin, may, as with any injection, experience increased bruising or bleeding at the injection site. Universal precautions must be observed when there is a potential for contact with patient body fluids. The injection session must be conducted with aseptic technique. After use, treatment syringes and needles may be potential biohazards. Handle accordingly and dispose of in accordance with accepted medical practice and applicable local, state and federal requirements. The patient should be informed that he or she should minimize exposure of the treated area to extensive sun or heat exposure for approximately 24 hours after treatment or until any initial swelling and redness has resolved. Safety and effectiveness in the periorbital area has not been established. No studies of interactions of RADIESSE injectable implant with drugs or other substances or implants have been conducted. The safety of RADIESSE injectable implant with concomitant dermal therapies such as epilation, UV irradiation, or laser, mechanical or chemical peeling procedures has not been evaluated in controlled clinical trials. If laser treatment, chemical peeling, or any other procedure based on active dermal response is considered after treatment with RADIESSE injectable implant, there is a possible risk of eliciting an inflammatory reaction at the implant site. This also applies if RADIESSE injectable implant is administered before the skin has healed completely after such a procedure. To help avoid needle breakage, do not attempt to straighten a bent needle. Discard it and complete the procedure with a replacement needle. Do not reshield used needles. Recapping by hand is a hazardous practice and should be avoided. Injection of RADIESSE injectable implant into patients with a history of previous herpetic eruption may be associated with reactivation of the herpes. Patient Counseling Information Refer to RADIESSE injectable implant PATIENT INFORMATION Guide.

More Medical Conditions

A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z

Medical Conditions Definitions Of The Day