Clinical Pharmacology

CLINICAL PHARMACOLOGY Action GELFOAM has hemostatic properties. While its mode of action is not fully understood, its effect appears to be more physical than the result of altering the blood clotting mechanism. When not used in excessive amounts, GELFOAM is absorbed completely, with little tissue reaction. This absorption is dependent on several factors, including the amount used, degree of saturation with blood or other fluids, and the site of use. When placed in soft tissues, GELFOAM is usually absorbed completely in from four to six weeks, without inducing excessive scar tissue. When applied to bleeding nasal, rectal or vaginal mucosa, it liquefies within two to five days. Animal Pharmacology Surface-acting hemostatic devices, when applied directly to bleeding surfaces, arrest bleeding by providing a mechanical matrix that facilitates clotting.6,8,13,14 Due to their bulk, surface-acting hemostatic agents slow the flow of blood, protect the forming clot, and offer a framework for deposition of the cellular elements of blood.6,7,8,13 MacDonald and Mathews12 studied GELFOAM implants in canine kidneys and reported that it assisted in healing, with no marked inflammatory or foreign-body reactions. Jenkins and Janda13 studied the use of GELFOAM in canine liver resections and noted that the gelatin sponge appeared to offer a protective cover and provide structural support for the reparative process. Correll et all14 studied the histology of GELFOAM Sterile Sponge when implanted in rat muscle and reported no significant tissue reaction. Clinical Studies GELFOAM Sterile Powder is a water-insoluble, hemostatic device prepared from purified skin gelatin, and capable of absorbing up to 45 times its weight of whole blood.4 The absorptive capacity of GELFOAM is a function of its physical size, increasing as the amount of the gelatin powder increases.5 The mechanism of action of surface-mediated hemostatic devices is supportive and mechanical.5 Surface acting devices, when applied directly to bleeding surfaces, arrest bleeding by the formation of an artificial clot and by producing a mechanical matrix that facilitates clotting.6 Jenkins et al7 have theorized that the clotting effect of GELFOAM may be due to release of thromboplastin from platelets, occurring when platelets entering the sponge become damaged by contact with the walls of its myriad of interstices. Thromboplastin interacts with prothrombin and calcium to produce thrombin, and this sequence of events initiates the clotting reaction. The authors suggest that the physiologic formation of thrombin in the sponge is sufficient to produce formation of a clot, by its action on the fibrinogen in blood.7 The spongy physical properties of the gelatin sponge hasten clot formation and provide structural support for the forming clot.6,8 Several investigators have claimed that GELFOAM becomes liquefied within a week or less and is completely absorbed in four to six weeks, without inducing excessive scar formation.4,7,9,10,11 Barnes10 reviewed experiences with GELFOAM in gynecologic surgery. No excessive scar tissue, attributable to the absorption of GELFOAM, could be palpated at postoperative examination. Bone Hemostasis Study The efficacy of GELFOAM Sterile Powder as a bone hemostatic agent during cardiopulmonary bypass surgery was evaluated. Study Design Two randomized open-label clinical studies were conducted at separate investigative sites. The objectives were as follows: To evaluate the effectiveness of GELFOAM Sterile Powder as a hemostatic agent in the treatment of sternal bone bleeding during cardiopulmonary bypass surgery. To identify any deleterious effects of GELFOAM Sterile Powder on interference with bone healing. To determine any systemic or local wound side effects from leaving GELFOAM Sterile Powder in situ. Patients between the ages of 18 to 74 years old undergoing cardiopulmonary bypass surgery were randomly assigned to either a GELFOAM group or a Control group. The GELFOAM group (composed of 108 patients) had a paste made up of sterile saline solution and GELFOAM Sterile Powder applied to the cut sternal surface immediately following sternotomy. The Control group (composed of 107 patients received no treatment applied to the cut surface. Blood loss was monitored both during surgery and postoperatively. Blood loss during surgery was determined by measuring the weight of the powder before and after application to the cut edge of the sternum. Postoperative blood loss was collected from the mediastinal drainage tubes. The total blood loss (in milligrams) over 72 hours was determined for each patient. Study Endpoints Patients were evaluated upon admission (preoperative), during surgery (intraoperative), after surgery (postoperative), upon hospital discharge (7 to 10 days after surgery), and at the 3-month follow-up visit. An additional poststudy follow-up was required if a patient reported an ongoing medical event at the 3-month follow-up visit. Study Results In both studies, the amount of blood loss was significantly less in the GELFOAM group than in the Control group. In Study 001, the mean blood loss in the GELFOAM group was 13727.7 mg while the mean blood loss in the Control group was more than double at 27712.0 mg. Similar results were found in Study 002, where the mean blood loss in the GELFOAM group was 9514.8 mg while the mean blood loss in the Control group was 22687.5 mg. Table 2: Blood Loss in Sternotomy Patients Site 001 Site 002 GELFOAM Control GELFOAM Control Mean Blood Loss (mg) 13727.7 27712.0 9514.8 22687.5 Median Blood Loss (mg) 11561.0 24798.0 6950.0 16900.0 Minimum Blood Loss (mg) 2922.0 10748.0 800.0 900.0 Maximum Blood Loss (mg) 87448.0 61535.0 46000.0 89800.0 Patients in the GELFOAM and Control groups were similar with regard to sterna bone healing. At hospital discharge, normal bone healing was reported for 105 patients (97%) in the GELFOAM group and 104 patients (97%) in the Control group. At the 3-month follow-up, 103 patients (95%) in the GELFOAM group and 100 patients (93%) in the Control group were healed. Few patients in either treatment group had sternotomy infection or other postoperative infection complications related to sternotomy. At hospital discharge, two patients treated with GELFOAM had mediastinitis. No Control patients had any infections at hospital discharge. One patient treated with GELFOAM had a non-infection related complication. At the 3-month follow-up, one of the original patients treated with GELFOAM who had mediastinitis still showed signs of infection. In addition, two additional patients treated with GELFOAM developed mediastinitis at the 3-month follow-up. One patient in the Control group experienced sternal osteomyelitis at the 3-month follow-up but recovered with no residual effects. No patients from the GELFOAM arm of the study had reported complications of sternal osteomyelitis. There was a total of four Control patients who had non-infection-related complications. One Control patient had serous/sanguineous wound drainage from the left leg and sternum incisions at hospital discharge. This complication was non-infectious and the patient recovered with no residual side effects. Three Control patients all experienced chronic pain syndrome, a symptom which can occur following thoracic/cardiac surgery. Evaluation sternal bone healing at the 3-month follow-up for these patients showed no evidence of non-union of the sternum. In all three cases, bone healing at the 3-month follow-up was reported as being normal. A summary of sternotomy infection information is located in Table 3. Table 3: Summary of Postoperative Infection Complications Hospital Discharge 3-Month Follow-up GELFOAM Control GELFOAM Control N % N % N % N % Any Infection yes 1 (1) 0 (0) 5 (5) 0 (0) no 104 (99) 106 (100) 95 (95) 105 (100) Superficial Wound yes 0 (0) 0 (0) 2 (2) 0 (0) no 105 (100) 106 (100) 98 (98) 105 (100) Sternal Osteomyelitis yes 0 (0) 0 (0) 1 (1) 1 (1) no 105 (100) 106 (100) 99 (99) 105 (99) Mediastinitis yes 1 (1) 0 (0) 2 (2) 0 (0) no 104 (99) 106 (100) 98 (98) 105 (100) Complication Related to Sternotomy yes 0 (0) 0 (0) 1 (1) 3 (3) no 105 (100) 106 (100) 99 (99) 102 (97) Study Conclusions These studies demonstrate that a paste made from GELFOAM Sterile Powder is safe and effective in treating intraoperative bleeding when applied to the cut surface of cancellous bone and has shown superior hemostasis versus no treatment at all to the cut bone surface. The benefit to patients is that a reduction in bleeding will make surgery easier to perform by reducing the time the surgeon needs to revisit cut bone surfaces to clean up the bleeding. This study also demonstrated that GELFOAM Sterile Powder could be left in situ without increased risk of bone infection or nonunion of the sternum. REFERENCES 1. Lindstrom PA: Complications from the use of absorbable hemostatic sponges. AMA Arch Surg 1956;73:133-141. 2. Knowlson GTG: Gelfoam granuloma in the brain. J Neuro Neurosurg Psychiatry 1974;37:971-973. 3. Herndon JH, Grillo HC, Riseborough EJ, et al: Compression of the brain and spinal cord following use of GELFOAM. Arch Surg 1972;104:107. 4. Council on Pharmacy and Chemistry: Absorbable Gelatin sponge – new and nonofficial remedies. JAMA 1947;135:921. 5. Goodman LS, Gilman A: Surface-acting drugs, in The Pharmacologic Basis of Therapeutics, ed 6. New York, MacMillan Publishing Co. 1980, p 955. 6. Guralnick W, Berg L: GELFOAM in oral surgery. Oral Surg 1948;1:629-632. 7. Jenkins HP, Senz EH, Owen H, et al: Present status of gelatin sponge for control of hemorrhage. JAMA 1946;132:614-619. 8. Jenkins HP, Janda R, Clarke J: Clinical and experimental observations on the use of gelatin sponge or foam. Surg 1946;20:124-132. 9. Treves N: Prophylaxis of post mammectomy lymphedema by the use of GELFOAM laminated rolls. Cancer 1952;5:73-83. 10. Barnes AC: The use of gelatin foam sponges in obstetrics and gynecology. Am J Obstet Gynecol 1963;86:105-107. 11. Rarig HR: Successful use of gelatin foam sponge in surgical restoration of fertility. Am J Obstet Gynecol 1963;86:136. 12. MacDonald SA, Mathews WH: Fibrin foam and GELFOAM in experimental kidney wounds. Annual American Urological Association, July 1946. 13. Jenkins HP, Janda R: Studies on the use of gelatin sponge or foam as a hemostatic agent in experimental liver resections and injuries to large veins. Ann Surg 1946;124:952-961. 14. Correll JT, Prentice HR, Wise EC: Biologic investigations of a new absorbable sponge. Surg Gynecol Obstet 1945;181:585-589.

Drug Description

Find Lowest Prices on Gelfoam® absorbable gelatin powder (absorbable gelatin powder from absorbable gelatin sponge, USP) DESCRIPTION GELFOAM is a medical device intended for application to bleeding surfaces as a hemostatic. It is a water-insoluble, off-white, nonelastic, porous, pliable product prepared from purified pork Skin Gelatin USP Granules and Water for Injection, USPand is able to absorb and hold within its interstices, many times its weight of blood and other fluids. GELFOAM Sterile Powder is a fine, dry, heat-sterilized light powder prepared by milling absorbable gelatin sponge.

Indications & Dosage

INDICATIONS Hemostasis GELFOAM Sterile Powder, saturated with sterile sodium chloride solution, is indicated in surgical procedures, including those involving cancellous bone bleeding, as a hemostatic device, when control of capillary, venous, and arteriolar bleeding by pressure, ligature, and other conventional procedures is either ineffective or impractical. Although not necessary, GELFOAM can be used either with or without thrombin to obtain hemostasis. Directions For Use GELFOAM Sterile Powder can be saturated with sterile, isotonic sodium chloride solution (sterile saline) or a solution of thrombin1, before use as an adjunct to hemostasis. The envelope of GELFOAM Sterile Powder should be opened and the contents (1 gram) poured carefully into a sterile beaker, avoiding contamination. Using sterile technique, a puttylike paste is prepared by adding a total of approximately 3-4 mL of sterile saline or thrombin solution1 to the GELFOAM. If a mixture of less viscosity is desired, 7-10 mL of sterile saline or thrombin solution may be utilized. Dispersion of the powder can be avoided by initially compressing it with the gloved fingers into the bottom of the beaker and then kneading it into the desired consistency. The resulting doughy paste may be smeared or pressed against the bleeding surface to control bleeding. When bleeding stops the excess should be removed. Use only the minimum amount of GELFOAM, necessary to produce hemostasis. The GELFOAM may be left in place at the bleeding site, when necessary. Since GELFOAM causes little more cellular reaction than does the blood clot, the wound may be closed over it. GELFOAM may be left in place when applied to mucosal surfaces until it liquefies. For use with thrombin, consult the thrombin insert for complete prescribing information and proper sample preparation. DOSAGE AND ADMINISTRATION Sterile technique should always be used. The minimum amount of GELFOAM should be applied to the bleeding site (see Directions For Use) with pressure until hemostasis is observed. Opened envelopes of unused GELFOAM should always be discarded. HOW SUPPLIED GELFOAM Sterile Powder (absorbable gelatin powder) is supplied in envelopes containing 1 gram: GTIN 00300090433048 (0009-0433-04). Storage And Handling GELFOAM Sterile Powder should be stored at 25°C (77°F); excursions permitted to 15-30°C (59-86°F) [see USP Controlled Room Temperature]. Once the envelope is opened, contents are subject to contamination. It is recommended that GELFOAM be used as soon as the envelope is opened and unused contents discarded.This product is prepackaged sterile and intended only for single use. Reuse can result in transmission of bloodborne pathogens (including HIV and hepatitis), potentially endangering patients and health care providers. Adherence to the principles of aseptic technique when using this product is essential. Caution Federal law restricts this device to sale by or on the order of a physician. REFERENCES 1 Prepared as per label recommendations. Manufactured by: Pharmacia and Upjohn Company, 7000 Portage Road, Kalamazoo, Michigan 49001, USA 1-800-253-8600, LAB-0307-6.0. Distributed by: Pharmacia & Upjohn Co., Division of Pfizer Inc., New York, NY 10017. Revised December 2014.

Medication Guide

PATIENT INFORMATION No information provided. Please refer to the WARNINGS AND PRECAUTIONS sections.

Overdosage & Contraindications

OVERDOSE No information provided. CONTRAINDICATIONS GELFOAM should not be used in closure of skin incisions because it may interfere with healing of the skin edges. This is due to mechanical interposition of gelatin and is not secondary to intrinsic interference with wound healing. GELFOAM should not be placed in intravascular compartments, because of the risk of embolization. Do not use GELFOAM Sterile Powder in patients with known allergies to porcine collagen.

Side Effects & Drug Interactions

SIDE EFFECTS There have been reports of fever associated with the use of GELFOAM, without demonstrable infection. GELFOAM may serve as a nidus for infection and abscess formation1, and has been reported to potentiate bacterial growth. Giant-cell granuloma has been reported at the implantation site of absorbable gelatin product in the brain2, as has compression of the brain and spinal cord resulting from the accumulation of sterile fluid.3 Foreign body reactions, “encapsulation” of fluid and hematoma have also been reported. When GELFOAM was used in laminectomy operations, multiple neurologic events were reported, including but not limited to cauda equina syndrome, spinal stenosis, meningitis, arachnoiditis, headaches, paresthesias, pain, bladder and bowel dysfunction, and impotence. Excessive fibrosis and prolonged fixation of a tendon have been reported when absorbable gelatin products were used in severed tendon repair. Toxic shock syndrome has been reported in association with the use of GELFOAM in nasal surgery. Fever, failure of absorption, and hearing loss have been reported in association with the use of GELFOAM during tympanoplasty. Adverse Reactions Reported From Unapproved Uses GELFOAM is not recommended for use other than as an adjunct for hemostasis. While some adverse medical events following the unapproved use of GELFOAM have been reported to Pharmacia & Upjohn Company (see ADVERSE REACTIONS above), other hazards associated with such use may not have been reported. When GELFOAM has been used during intravascular catheterization for the purpose of producing vessel occlusion, the following adverse events have been reported; fever, duodenal and pancreatic infarct, embolization of lower extremity vessels, pulmonary embolization, splenic abscess, necrosis of specific anatomic areas, asterixis, and death. These adverse medical events have been associated with the use of GELFOAM for repair of dural defects encountered during laminectomy and craniotomy operations: fever, infection, leg paresthesias, neck and back pain, bladder and bowel incontinence, cauda equina syndrome, neurogenic bladder, impotence, and paresis. Adverse Events Associated With Bone Hemostasis In a clinical study, 108 patients received GELFOAM Sterile Powder on the cut surface of the sternum during cardiopulmonary bypass surgery, while 107 patients received no treatment on the cut surface of the bone. Table 1 is a summary of medical events reported by at least 1.0% of patients in a treatment group. The most frequently reported events were atrial fibrillation, perioperative event, and wound infection. Events occurring in less than 1.0% of the patients were as follows: anaphylaxis, cardiogenic shock, delirium tremens, infection at the vascular catheter site, unevaluable reaction, sepsis, angina pectoris, atrial arrhythmia, nodal arrhythmia, arteriosclerosis, cardiac insufficiency, cardiac tamponade, cardiomyopathy, deep vein thrombosis, mitral valve disorder, endocarditis, ventricular extrasystoles, heart arrest, hypotension, mesenteric occlusion, superventricular tachycardia, thrombophlebitis, thrombosis, gastrointestinal disorder, gastrointestinal bleeding, increased serum creatinine, dehydration, anemia, thrombocytopenia, abnormal healing, hypovolemia, hypoxia, metabolic acidosis, cerebral infarction, visual hallucinations, stupor, aspiration pneumonia, chest congestion, pleural effusion, pulmonary infiltration, retinal artery occlusion, anuria, UG disorder, abnormal kidney function and menorrhagia. Table 1: Summary of Medical Events for GELFOAM Sterile Powder when used as a Bone Hemostatic Agent During Cardiopulmonary Bypass Surgery Medical Event GELFOAM N=108 Control N=107 Total N=215 n % n % n % Atrial Fibrillation 14 (13) 12 (11) 26 (12) Wound Infection 6 (6) 1 (0.9) 7 (3.3) Perioperative Event 4 (4) 5 (4.7) 9 (4.2) Congestive Heart Failure 4 (4) 0 (0) 4 (1.9) Ventricular Tachycardia 2 (2) 3 (2.8) 5 (2.3) Atrial Flutter 2 (2) 0 (0) 2 (0.9) Peripheral Vascular Disorder 2 (2) 0 (0) 2 (0.9) Pneumothorax 2 (2) 3 (2.8) 5 (2.3) Respiratory Failure 2 (2) 2 (1.9) 4 (1.9) Respiratory Arrest 2 (2) 1 (0.9) 3 (1.4) Fever 1 (1) 2 (1.9) 3 (1.4) Heart Block 1 (1) 2 (1.9) 3 (1.4) Prolonged Wound Drainage 0 (0) 1 (0.9) 1 (0.5) Cellulitis 0 (0) 2 (1.9) 2 (0.9) Dyspnea 0 (0) 2 (1.9) 2 (0.9) Pneumonia 0 (0) 2 (1.9) 2 (0.9) In general, the following adverse events have been reported with the use of absorbable porcine gelatin-based hemostatic agents: Gelatin-based hemostatic agents may serve as a nidus for infection and abscess formation and have been reported to potentiate bacterial growth. Giant cell granulomas have been observed at implant sites when used in the brain. Compression of the brain and spinal cord resulting from the accumulation of sterile fluid has been observed. Multiple neurologic events were reported when absorbable gelatin-based hemostatic agents were used in laminectomy operations, including cauda equina syndrome, spinal stenosis, meningitis, arachnoiditis, headaches, paresthesias, pain, bladder and bowel dysfunction, and impotence and paresis. The use of absorbable gelatin-based hemostatic agents have been associated with paralysis, due to device migration into foramina in the bone around the spinal cord, and blindness due to device migration in the orbit of the eye, during lobectomy, laminectomy and repair of a frontal skull fracture and lacerated lobe. Foreign body reactions, “encapsulation” of fluid, and hemotoma have been observed at implant sites. Excessive fibrosis and prolonged fixation of a tendon have been reported when absorbable gelatin-based sponges were used in severed tendon repair. Toxic shock syndrome was reported in association with the use of absorbable gelatin-based hemostats in nasal surgery. Fever, failure of absorption, and hearing loss have been observed when absorbable hemostatic agents were used during tympanoplasty. DRUG INTERACTIONS No information provided.

Warnings & Precautions

WARNINGS GELFOAM is not intended as a substitute for meticulous surgical technique and the proper application of ligatures, or other conventional procedures for hemostasis. GELFOAM is supplied as a sterile product and cannot be resterilized. Unused, opened envelopes of GELFOAM should be discarded. To prevent contamination, employ aseptic procedure in opening envelope and withdrawing GELFOAM. If the envelope is torn or punctured, the contained GELFOAM should not be used. Only the minimum amount of GELFOAM necessary to achieve hemostasis should be used. Once hemostasis is attained, excess GELFOAM should be carefully removed. The use of GELFOAM is not recommended in the presence of infection. GELFOAM should be used with caution in contaminated areas of the body. If signs of infection or abscess develop where GELFOAM has been positioned, reoperation may be necessary in order to remove the infected material and allow drainage. Although the safety and efficacy of the combined use of GELFOAM with other agents such as topical thrombin has not been evaluated in controlled clinical trials, if in the physician's judgment concurrent use of other agents is medically advisable, the product literature for that agent should be consulted for complete prescribing information. While packing a cavity for hemostasis is sometimes surgically indicated, GELFOAM should not be used in this manner unless excess product not needed to maintain hemostasis is removed. Whenever possible, it should be removed after use in laminectomy procedures and from foramina in bone, once hemostasis is achieved. This is because GELFOAM may swell on absorbing fluids, and produce nerve damage by pressure within confined bony spaces. The packing of GELFOAM, particularly within bony cavities, should be avoided, since swelling may interfere with normal function and/or possibly result in compression necrosis of surrounding tissues. PRECAUTIONS The minimum amount of GELFOAM Sterile Powder needed for hemostasis should be applied together with pressure until the bleeding stops. The excess should then be removed. GELFOAM should not be used for controlling postpartum hemorrhage or menorrhagia. It has been demonstrated that fragments of another hemostatic agent, microfibrillar collagen, pass through the 40μ transfusion filters of blood scavenging systems. GELFOAM should not be used in conjunction with autologous blood salvage circuits since the safety of this use has not been evaluated in controlled clinical trials. Microfibrillar collagen has been reported to reduce the strength of methylmethacrylate adhesives used to attach prosthetic devices to bone surfaces. As a precaution, GELFOAM should not be used in conjunction with such adhesives. GELFOAM is not recommended for the primary treatment of coagulation disorders. It is not recommended that GELFOAM be saturated with an antibiotic solution or dusted with antibiotic powder. Positioning of the patient resulting in negative peripheral venous pressure during a procedure has been reported to be a contributing factor resulting in life-threatening thromboembolic events.