About The Drug Ruby-fill aka Rubidium Rb 82 Generator

ClusterMed

Find Ruby-fill side effects, uses, warnings, interactions and indications. Ruby-fill is also known as Rubidium Rb 82 Generator.

Ruby-fill

Ruby-fill Prescription Drug Bottle
About Ruby-fill aka Rubidium Rb 82 Generator

What's The Definition Of The Medical Condition Ruby-fill?

Clinical Pharmacology

CLINICAL PHARMACOLOGY Mechanism Of Action Rb 82 is analogous to potassium ion (K+) in its biochemical behavior and is rapidly extracted by the myocardium proportional to the blood flow. Rb+ participates in the sodium-potassium (Na+/K+) ion exchange pumps that are present in cell membranes. The intracellular uptake of Rb 82 requires maintenance of ionic gradient across cell membranes. Rb 82 radioactivity in viable myocardium is higher than in infarcted tissue, reflecting intracellular retention. Pharmacodynamics In human studies, myocardial activity was noted within the first minute after peripheral intravenous injection of Rb 82. When areas of infarction or ischemia are present in the myocardium, they are visualized within 2-7 minutes after injection as photon-deficient, or “cold”, areas on the myocardial perfusion scan. In patients with reduced cardiac function, transit of the injected dose from the peripheral infusion site to the myocardium may be delayed. Blood flow brings Rb 82 to all areas of the body during the first pass of circulation. Accordingly, visible uptake is observed in highly vascularized organs, such as the kidneys, liver, spleen and lungs. Pharmacokinetics With a physical half-life of 75 seconds, Rb 82 is converted by radioactive decay into stable Kr 82 gas, which is passively expired by the lungs. Clinical Studies In a descriptive, prospective, blinded image interpretation study of adult patients with known or suspected coronary artery disease, myocardial perfusion deficits in stress and rest PET images obtained with ammonia N 13 (n = 111) or Rb 82 (n = 82) were compared to changes in stenosis flow reserve (SFR) as determined by coronary angiography. PET perfusion defects at rest and stress for seven cardiac regions (anterior, apical, anteroseptal, posteroseptal, anterolateral, posterolateral, and inferior walls) were graded on a scale of 0 (normal) to 5 (severe). Values for stenosis flow reserve, defined as flow at maximum coronary vasodilatation relative to rest flow, ranged from 0 (total occlusion) to 5 (normal). With increasing impairment of flow reserve, the subjective PET defect severity increased. A PET defect score of 2 or higher was positively correlated with flow reserve impairment (SFR < 3). A systematic review of published literature was conducted using pre-defined inclusion/exclusion criteria which resulted in identification of 10 studies evaluating the use of Rb 82 PET myocardial perfusion imaging (MPI) for the identification of coronary artery disease as defined by catheter-based angiography. In these studies, the patient was the unit of analysis and 50% stenosis was the threshold for clinically significant coronary artery disease (CAD). Of these 10 studies, 9 studies were included in a meta-analysis for sensitivity (excluding one study with 100% sensitivity) and 7 studies were included in a meta-analysis of specificity (excluding 3 studies with 100% specificity). A random effects model yielded overall estimates of sensitivity and specificity of 92% (95% CI: 89% to 95%) and 81% (95% CI: 76% to 86%), respectively. The use of meta-analysis in establishing performance characteristics is limited, particularly by the possibility of publication bias (positive results being more likely to be published than negative results) which is difficult to detect especially when based on a limited number of small studies.

Drug Description

RUBY-FILL (rubidium Rb 82) Generator WARNING UNINTENDED STRONTIUM 82 (Sr 82) AND STRONTIUM 85 (Sr 85) RADIATION EXPOSURE Unintended radiation exposure occurs when the levels of Sr 82 or Sr 85 in the rubidium Rb 82 chloride injection exceed specified limits [see WARNINGS AND PRECAUTIONS]. Perform generator eluate tests: The system automatically generates a record and saves the data for each generator eluate volume, including flushing and test volumes. Total cumulative eluate volumes are also recorded and saved for the life of the generator [see DOSAGE AND ADMINISTRATION]. Determine Rb 82, Sr 82, Sr 85 in the generator eluate: Once a day, prior to any drug administration, and At additional daily tests after detection of an Alert Limit. Alert Limits are: 20 L for the generator's cumulative eluate volume, or An eluate Sr 82 level of 0.004 μCi/ mCi (kBq/MBq) Rb 82, or An eluate Sr 85 level of 0.04 μCi/ mCi (kBq/MBq) Rb 82. Perform additional daily tests every 4 patients after detection of an alert limit [see DOSAGE AND ADMINISTRATION]. Stop use of a generator at any of the following Expiration Limits. Expiry Limits are: 30 L for the generator's cumulative eluate volume, or Expiration date of the generator (60 days post-manufacturing) An eluate Sr 82 level of 0.01 μCi /mCi (kBq/MBq) Rb 82, or An eluate Sr 85 level of 0.1 μCi /mCi (kBq/MBq) Rb 82 [see DOSAGE AND ADMINISTRATION]. DESCRIPTION Chemical Characteristics RUBY-FILL Rubidium Rb 82 Generator contains accelerator-produced Sr 82 adsorbed on stannic oxide in a lead-shielded column and provides a means for obtaining sterile non-pyrogenic solutions of rubidium Rb 82 chloride injection. The chemical form of Rb 82 is 82RbCl. The amount (mCi) of Rb 82 obtained in each elution will depend on the potency of the generator. When used with the RUBY Rubidium Elution System, the generator provides ± 10% accuracy for rubidium Rb 82 chloride doses between 370-2220 MBq (10-60 mCi). When eluted at a rate of 15 -30 mL/minute, each generator eluate at the end of elution should not contain more than 0.02 μCi (0.74 kBq) of Sr 82 and not more than 0.2 μCi (7.4 kBq) of Sr 85 per mCi of rubidium Rb 82 chloride injection, and not more than 1 μg of tin per mL of eluate. Physical Characteristics Rb 82 decays by positron emission and associated gamma emission with a physical half-life of 75 seconds. Table 5 shows the annihilation photons released following positron emission which are useful for detection and imaging studies. The decay modes of Rb 82 are: 95.5% by positron emission, resulting in the production of annihilation radiation, i.e., two 511 keV gamma rays; and 4.5% by electron capture, resulting in the emission of “prompt” gamma rays of predominantly 776.5 keV. Both decay modes lead directly to the formation of stable Kr 82. TABLE 5 : Principal Radiation Emission Data Radiation Mean Percent Per Disintegration Mean Energy (keV) Annihilation photons (2) 191.01 511 (each) Gamma rays 13 to 15 776.5 The specific gamma ray constant for Rb-82 is 6.33 R cm² / mCi h (1.23 × 10-12 C m² / kg MBq s). The first half-value layer is 0.53 cm of lead (Pb). Table 6 shows a range of values for the relative attenuation of the radiation emitted by this radionuclide that results from interposition of various thicknesses of Pb. For example, the use of a 6.15 cm thickness of Pb will attenuate the radiation emitted by a factor of about 1,000. TABLE 6 : Radiation Attenuation by Lead Shielding Shield Thickness (Pb) cm Attenuation Factor 0.53 0.5 1.68 10-1 3.55 10-2 6.15 10-3 9.3 10-4 Sr 82 (half-life of 25 days; 600 hrs.) decays to Rb 82. To correct for physical decay of Sr 82, Table 7 shows the fractions that remain at selected intervals after the time of calibration. TABLE 7 : Physical Decay Chart: Sr 82 half-life 25 days Days Fraction Remaining Days Fraction Remaining Days Fraction Remaining 0* 1.000 21 0.559 41 0.321 1 0.973 22 0.543 42 0.312 2 0.946 23 0.529 43 0.304 3 0.920 24 0.514 44 0.295 4 0.895 25 0.500 45 0.287 5 0.871 26 0.486 46 0.279 6 0.847 27 0.473 47 0.272 7 0.824 28 0.460 48 0.264 8 0.801 29 0.448 49 0.257 9 0.779 30 0.435 50 0.250 10 0.758 31 0.423 51 0.243 11 0.737 32 0.412 52 0.237 12 0.717 33 0.401 53 0.230 13 0.697 34 0.390 54 0.224 14 0.678 35 0.379 55 0.218 15 0.660 36 0.369 56 0.212 16 0.642 37 0.358 57 0.206 17 0.624 38 0.349 58 0.200 18 0.607 39 0.339 59 0.195 19 0.591 40 0.330 60 0.189 20 0.574 * Calibration time To correct for physical decay of Rb 82, Table 1 shows the fraction of Rb 82 remaining in all 15 second intervals up to 300 seconds after time of calibration [see DOSAGE AND ADMINISTRATION].

Indications & Dosage

INDICATIONS RUBY-FILL is a closed system used to produce rubidium Rb 82 chloride injection for intravenous administration. Rubidium Rb 82 chloride injection is indicated for Positron Emission Tomography (PET) imaging of the myocardium under rest or pharmacologic stress conditions to evaluate regional myocardial perfusion in adult patients with suspected or existing coronary artery disease. DOSAGE AND ADMINISTRATION Radiation Safety -Drug Handling Rubidium Rb 82 is a radioactive drug and should be handled with appropriate safety measures to minimize radiation exposure during administration [see WARNINGS AND PRECAUTIONS]). Use waterproof gloves and effective shielding when handling rubidium Rb 82 chloride injection and the RUBY Rubidium Elution System. Use aseptic techniques in all drug handling. Visually inspect the drug for particulate matter and discoloration prior to administration whenever solution and container permit. Do not administer eluate from the generator if there is any evidence of foreign matter. Recommended Dose And Administration Instructions The recommended weight-based dose of rubidium Rb 82 chloride to be administered per rest or stress component of a PET myocardial perfusion imaging (MPI) procedure is between 10-30 Megabecquerels (MBq)/kg [0.27-0.81 millicuries (mCi)/kg]. Do not exceed a single dose of 2220 MBq (60 mCi). Use the lowest dose necessary to obtain adequate cardiac visualization and individualize the weight-based dose depending on multiple factors, including, patient weight, imaging equipment and acquisition type used to perform the procedure. For example, 3D imaging acquisition may require doses at the lower end of the recommended range compared to 2D imaging. Administer the single dose at a rate of 15 -30 mL/minute through a catheter inserted into a large peripheral vein; do not exceed an infusion volume of 60 mL. Instruct patients to void as soon as a study is completed and as often as possible thereafter for at least one hour. The maximum available activity (delivery limit) will decrease as the generator ages [see RUBY-FILL Dose Delivery Limit]. Image Acquisition Guidelines For Rest Imaging: Administer a single (“rest”) rubidium Rb 82 chloride dose; Start imaging 60-90 seconds after completion of the infusion of the rest dose and acquire images for 3-7 minutes. For Stress Imaging: Begin the study 10 minutes after completion of the resting dose infusion, to allow for sufficient Rb 82 decay; Administer a pharmacologic stress agent in accordance with its prescribing information; After administration of the pharmacologic stress agent, administer the second dose of Rb 82 at the time interval according to the prescribing information of the pharmacological stress agent; Start imaging 60-90 seconds after completion of the stress rubidium Rb 82 chloride dose infusion and acquire images for 3-7 minutes. For Both Rest and Stress Imaging: If a longer circulation time is anticipated (e.g., in a patient with severe left ventricular dysfunction), start imaging 120 seconds after the rest dose. Acquisition may be started immediately post-injection if dynamic imaging is needed. Elution System Use RUBY-FILL Rubidium Rb 82 Generator only with an elution system specifically designed for use with the generator (RUBY Rubidium Elution System) and capable of accurate measurement and delivery of doses of rubidium Rb 82 chloride injection. The generator used with the elution system provides ± 10% accuracy for rubidium Rb 82 chloride doses between 370-2220 MBq (10-60 mCi) Follow instructions in the RUBY Rubidium Elution System User Manual for the set up and intravenous infusion of rubidium Rb 82 chloride injection dose. Directions For Eluting Rubidium Rb 82 Chloride Injection Allow at least 10 minutes between elutions for regeneration of Rb 82. Elute with additive-free 0.9% Sodium Chloride Injection USP only. Additives (particularly calcium ions, to which strontium ions are chemically analogous), may cause the release of substantial amounts of Sr 82 and/or Sr 85 into the eluate regardless of the age or prior use of the generator. The system will automatically discard the first 75 mL eluate each day the generator is first eluted. The RUBY Rubidium Elution System automatically generates records and saves data of all eluate volumes (from flushing, QC testing, patient infusions), representing the cumulative volume of eluate from the generator. Eluate Testing Protocol Elute with additive-free 0.9% Sodium Chloride Injection USP only. Use the ionization chamber-type dose calibrator that is integrated into the elution system (used specifically with the RUBYFILL Rubidium Rb 82 Generator) for eluate testing. Perform Mandatory Eluate Testing (i.e. Quality Control test) to determine Rb 82, Sr 82, and Sr 85 levels: Daily -Before administering rubidium Rb 82 chloride injection to the first patient each day. Repeat Every 4 patients after an Alert Limit has been detected. Alert Limits: 20 L total elution volume has passed through the generator column, or Sr 82 level reaches 0.004 μCi per mCi (kBq per MBq) Rb 82, or Sr 85 level reaches 0.04 μCi per mCi (kBq per MBq) Rb 82. 3. Immediately after detection of the volume alert limit (20 L). The elution system will automatically indicate when alert limits have been reached and require that additional tests be performed. When the Quality Control test is performed as described in the User Manual, the system automatically performs the following eluate testing: Rubidium Eluate Testing: The dose calibrator is automatically set for Rb 82 within the Elution System. The Quality Control test begins by automatically initiating a generator flush using 75 mL of 0.9% Sodium Chloride Injection USP. This eluate is by default diverted towards the waste container and is ultimately discarded. After the generator flush, the system waits approximately 15.2 minutes to accomplish a complete generator recharge of 12 Rb 82 half-lives The system then elutes a calibration sample (35 mL of 0.9% Sodium Chloride Injection USP at 20 mL/min). Using the dose calibrator, the system automatically quantifies the activity of Rb 82 in the calibration sample (Rb 82 decay does not need to be corrected for because of a real-time automated measurement). Strontium Eluate Testing (Strontium Breakthrough): Using the calibration sample obtained from the Rb 82 eluate testing, the system allows the sample to stand for 30 minutes to allow for the complete decay of Rb 82. The system measures the activity of the sample to automatically determine the total Sr 82 and Sr 85 activity. The system automatically determines the ratio (R) on the day (post calibration) of the measurement using the ratio of Sr 85/Sr 82 on the day of calibration provided on the generator label and the Sr 85/Sr 82 ratio factor from the Sr 85/Sr 82 ratio based on generator age using the following equation: R = [Sr 85]/ [Sr 82] on calibration date X Ratio Factor on the day (post-calibration) of measurement The system uses a correction factor (F) of 0.48 to compensate for the contribution of Sr 85 to the reading. The system calculates the amount of Sr 82 in the sample using the following equation: In Empirical Units (μCi): Sr 82 (μCi) = dose calibration reading (μCi) [1 + (R) (F)] Example: dose calibrator reading (μCi) = 0.8 Sr 85/Sr 82 ratio (R) = (1.48) correction factor (F) = 0.48 Sr 82 (μCi) = 0.8 μCi = 0.47 μCi [1 + (1.48)(0.48)] In International Units (kBq) Sr 82 (kBq) = dose calibration reading (μCi) [1 + (R) (F)] Example: dose calibrator reading (kBq) = 29.6 kBq Sr 85/Sr 82 ratio (R) = (1.48) correction factor (F) = 0.48 Sr 82 (kBq) = 29.6 kBq = 17.3 kBq [1 + (1.48)(0.48)] 6. The system determines if Sr 82 in the eluate exceeds an Alert or Expiration Limit by dividing the μCi (or kBq) of Sr 82 by the mCi (or MBq) of Rb 82 at End of Elution (see below for further instructions based on the Sr 82 level) In Empirical Units (μCi) Example: 0.47 μCi of Sr 82; 50 mCi of Rb 82 0.47 μCi Sr 82 = = 0.0094 μCi Sr 82 50 mCi Rb 82 mCi Rb 82 (Sr 82 is above Alert Limit of 0.004 μCi/mCi; additional daily eluate testing must be performed) In International Units (kBq) Example: 17.3 kBq of Sr 82; 1850 MBq of Rb 82 17.3 kBq Sr 82 = 0.0094 kBq Sr 82 1850 MBq Rb 82 MBq Rb 82 (Sr 82 is above Alert Limit of 0.004 kBq/MBq; additional daily eluate testing must be performed) 7. The system determines if Sr 85 in the eluate exceeds an Alert or Expiration Limit by multiplying the result obtained in step 6  by (R) as calculated in step 3 (above). In Empirical Units (μCi) Example: 0.0094 x 1.48 = 0.014 μCi Sr 85/mCi Rb 82 (Sr 85 test result is below Alert and Expiration Limits) In International Units (kBq) Example: 0.0094 x 1.48 = 0.014 kBq Sr 85/MBq Rb 82  (Sr 85 test result is below Alert and Expiration Limits) The system uses Table 1 to calculate the decay factor for Rb 82 TABLE 1 Physical Decay Chart: Rb 82 half-life 75 seconds Seconds Fraction Remaining Seconds Fraction Remaining 0* 1.00 165 0.218 15 0.871 180 0.190 30 0.758 195 0.165 45 0.660 210 0.144 60 0.574 225 0.125 75 0.500 240 0.109 90 0.435 255 0.095 105 0.379 270 0.083 120 0.330 285 0.072 135 0.287 300 0.063 150 0.250 *Elution time The system uses Table 2 to calculate the ratio (R) of Sr 85/Sr 82. TABLE 2 Sr 85/Sr 82 Ratio Chart (Sr 85 T½ = 65 days, Sr 82 T½ = 25 days) Days Ratio Factor Days Ratio Factor Days Ratio Factor 0* 1.00 21 1.43 42 2.05 1 1.02 22 1.46 43 2.08 2 1.03 23 1.48 44 2.12 3 1.05 24 1.51 45 2.15 4 1.07 25 1.53 46 2.19 5 1.09 26 1.56 47 2.23 6 1.11 27 1.58 48 2.27 7 1.13 28 1.61 49 2.30 8 1.15 29 1.64 50 2.34 9 1.17 30 1.67 51 2.38 10 1.19 31 1.70 52 2.43 11 1.21 32 1.73 53 2.47 12 1.23 33 1.76 54 2.51 13 1.25 34 1.79 55 2.55 14 1.27 35 1.82 56 2.60 15 1.29 36 1.85 57 2.64 16 1.31 37 1.88 58 2.69 17 1.34 38 1.91 59 2.73 18 1.36 39 1.95 60 2.78 19 1.38 40 1.98 20 1.41 41 2.01 * Day of calibration. RUBY-FILL Expiration Stop use of the RUBY-FILL Rubidium Rb 82 Generator once any one of the following Expiration Limits is reached: A total elution volume of 30 L has passed through the generator column, or Expiration date of the generator (60 days post-manufacturing), or An eluate Sr 82 level of 0.01 μCi/mCi (kBq/MBq) Rb 82, or An eluate Sr 85 level of 0.1 μCi/mCi (kBq/MBq) Rb 82. RUBY-FILL Dose Delivery Limit The maximum available activity (delivery limit) will decrease as the generator ages. Certain doses, including the maximum recommended dose [60 mCi (2220 MBq)], are not achievable for the entire shelf-life of the generator. Table 3 provides an estimate of the maximum available activity of Rubidium Rb 82 (Delivery Limit) as a function of generator age. Table 3 : Rubidium Rb 82 Dose Delivery Limit Based on Generator Age1 Generator Age (days) 2 Maximum Rubidium Dose (Delivery Limit) 0-17 60 mCi (2220 MBq) 24 50 mCi (1850 MBq) 32 40 mCi (1480 MBq) 42 30 mCi (1110 MBq) 57 20 mCi ( 740 MBq) 1Estimate is based on a 100 mCi (3700 MBq) Sr 82 generator at calibration. 2Generator age at which delivery limit is reached varies with generator activity at release. For example, an 85 mCi (3145 MBq) generator and a 115 mCi (4255 MBq) generator will reach a delivery limit < 60 mCi at ≥ 12 days and ≥ 23 days, respectively. Radiation Dosimetry The estimated radiation absorbed dose coefficients for Rb 82, Sr 82, and Sr 85 from an intravenous injection of rubidium Rb 82 chloride are shown in Table 4. Table 4 : Adult absorbed dose per radioisotope activity associated with injection Organ 82Rb1 (μGy/MBq) 82Sr2 (μGy/kBq) 85Sr2 (μGy/kBq) Adrenals 2.4 2.9 1.4 Bone surfaces 0.42 29 2.7 Brain 0.14 2.2 0.8 Breast 0.19 1.9 0.5 Gallbladder wall 0.72 2.3 0.8 Gastrointestinal tract Esophagus3 1.5 2.1 0.6 Stomach wall 0.83 2.1 0.6 Small intestine wall 2.0 2.6 1.1 Colon wall 1.1 9.7 1.2 (ULI wall) 1.1 6.4 1.0 (LLI wall) 1.1 14 1.4 Heart wall 4.0 2.2 0.7 Kidneys 9.3 2.5 0.7 Liver 1.0 2.2 0.7 Lungs 2.6 2.2 0.8 Muscles 0.23 2.2 0.7 Ovaries 0.50 2.8 1.2 Pancreas 2.6 2.5 0.9 Red marrow 0.38 25 2.7 Skin 0.18 1.9 0.5 Spleen 0.18 2.2 0.7 Testes 0.26 2.0 0.5 Thymus 1.5 2.1 0.6 Thyroid 0.31 2.2 0.7 Urinary bladder wall 0.18 5.9 0.8 Uterus 1.0 2.5 0.9 Remaining organs 0.31 - - Effective dose per unit activity 1.1μSv/MBq 6.3 μSv/kBq 1.1 μSv/kBq 1 Rb-82 doses are averages of rest and stress dosimetry data. To calculate organ doses (μGy) from Rb-82, multiply the dose coefficient for each organ by the administered activity in MBq. 2 To calculate organ doses attributable to Sr-82 and Sr-85, multiply those dose coefficients by the respective strontium activities associated with the injection. 3The absorbed dose to the thymus is used as a substitute. HOW SUPPLIED Dosage Forms And Strengths RUBY-FILL is a closed system used to produce rubidium Rb 82 chloride injection for intravenous use. RUBY-FILL consists of Sr 82 adsorbed on a hydrous stannic oxide column with an activity of 3145 -4255 MBq (85 -115 mCi) Sr 82 at calibration time. RUBY-FILL Rubidium Rb 82 Generator consists of Sr 82 adsorbed on a hydrous stannic oxide column with an activity of 3145 - 4255 MBq (85 -115 mCi) Sr 82 at calibration time. A lead shield encases the generator. The container label provides complete assay data for each generator. Use RUBY-FILL Rubidium Rb 82 Generator only with an appropriate, properly calibrated Elution System (RUBY Rubidium Elution System) labeled for use with the generator. Storage And Handling Store the generator at 20-25 °C (68-77 °F). Receipt, transfer, possession, storage, disposal or use of this product is subject to the radioactive material regulations and licensing requirements of the U.S. Nuclear Regulatory Commission (NRC), Agreement States or Licensing States as appropriate. Do not dispose of the generator in regular refuse systems. For questions about the disposal of the RUBY-FILL Rubidium Rb 82 Generator, contact Jubilant Draximage Inc. at 1-888633-5343. Manufactured by: Jubilant DRAXIMAGE Inc. 16751 TransCanada Highway Kirkland, Québec, Canada H9H 4J4. Revised: Sep 2016

Medication Guide

PATIENT INFORMATION Pregnancy Advise a pregnant woman of the potential risk to a fetus. Lactation Advise lactating women that exposure to Rb 82 chloride through breast milk can be minimized if breastfeeding is discontinued when Rb 82 chloride injection is administered. Advise lactating women not to resume breastfeeding for at least one hour after completion of rubidium Rb 82 infusion. General Safety Precautions Advise patients to void after completion of each image acquisition session and as often as possible for one hour after completion of the PET scan.

Overdosage & Contraindications

OVERDOSE No information provided. CONTRAINDICATIONS None.

Side Effects & Drug Interactions

SIDE EFFECTS The following serious adverse reaction associated with the use of rubidium Rb 82 chloride was identified in clinical trials or post marketing reports. Because these reactions are reported voluntarily from a population of uncertain size, it is not always possible to reliably estimate their frequency or establish a causal relationship to drug exposure. Unintended Sr 82 and Sr 85 Radiation Exposure: Unintended radiation exposure has occurred in some patients who received rubidium Rb 82 chloride injection at clinical sites where generator eluate testing appeared insufficient [see BOXED WARNING, WARNINGS AND PRECAUTIONS, DOSAGE AND ADMINISTRATION]. DRUG INTERACTIONS No information provided.

Warnings & Precautions

WARNINGS Included as part of the PRECAUTIONS section. PRECAUTIONS Unintended Sr 82 And Sr 85 Radiation Exposure Unintended radiation exposure occurs when the Sr 82 and Sr 85 levels in rubidium Rb 82 chloride injections exceed the specified generator eluate limits. To minimize the risk of unintended radiation exposure, strict adherence to a daily eluate testing protocol is required. Stop using the rubidium generator when the expiration limits are reached [see DOSAGE AND ADMINISTRATION]. Risks Associated With Pharmacologic Stress Pharmacologic induction of cardiovascular stress may be associated with serious adverse reactions such as myocardial infarction, arrhythmia, hypotension, bronchoconstriction, and cerebrovascular events. Perform pharmacologic stress testing in accordance with the pharmacologic stress agent's prescribing information and only in the setting where cardiac resuscitation equipment and trained staff are readily available. Radiation Risks RUBY-FILL use contributes to a patient's overall long-term cumulative radiation exposure. Long-term cumulative radiation exposure is associated with an increased risk for cancer. Ensure safe handling to minimize radiation exposure to the patient and health care providers. Encourage patients to void as soon as a study is completed and as often as possible thereafter for at least one hour [see DOSAGE AND ADMINISTRATION]. Nonclinical Toxicology Carcinogenesis, Mutagenesis, Impairment Of Fertility No long-term studies have been performed to evaluate carcinogenic potential, mutagenicity potential, or to determine whether rubidium Rb 82 chloride injection may affect fertility in males or females. Use In Specific Populations Pregnancy Risk Summary There are no data available on the use of rubidium Rb 82 in pregnant women. Animal reproduction studies with rubidium Rb 82 chloride have not been conducted. However, all radiopharmaceuticals have the potential to cause fetal harm depending on the fetal stage of development and the magnitude of the radiation dose. If considering rubidium Rb 82 chloride injection administration to a pregnant woman, inform the patient about the potential for adverse pregnancy outcomes based on the radiation dose from Rb 82 and the gestational timing of exposure. The estimated background risk of major birth defects and miscarriage for the indicated population is unknown. In the U.S. general population, the estimated background risk of major birth defects and miscarriage in clinically recognized pregnancies is 2-4% and 1520%, respectively. Lactation Risk Summary There is no information regarding the presence of Rb 82 chloride in human milk, the effects on the breastfed infant or the effects on milk production. Due to the short half-life of Rb 82 chloride (75 seconds), exposure of a breast fed infant through breast milk can be minimized by temporary discontinuation of breastfeeding [See Clinical Considerations]. The developmental and health benefits of breastfeeding should be considered along with the mother's clinical need for Rb 82, any potential adverse effects on the breastfed child from Rb 82 or from the underlying maternal condition. Clinical Considerations Minimizing Exposure Exposure to Rb 82 chloride through breast milk can be minimized if breastfeeding is discontinued when Rb 82 chloride injection is administered. Do not resume breastfeeding until at least one hour after completion of RUBY-FILL infusion. Pediatric Use The safety and effectiveness of rubidium Rb 82 chloride injection in pediatric patients have not been established. Geriatric Use In elderly patients with a clinically important decrease in cardiac function, lengthen the delay between infusion and image acquisition [see DOSAGE AND ADMINISTRATION]. Observe for the possibility of fluid overload from the infusion.

More Medical Conditions

A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z

Medical Conditions Definitions Of The Day