About The Drug Triamcinolone Acetonide Ointment aka Triamcinolone Ointment

ClusterMed

Find Triamcinolone Acetonide Ointment side effects, uses, warnings, interactions and indications. Triamcinolone Acetonide Ointment is also known as Triamcinolone Ointment.

Triamcinolone Acetonide Ointment

Triamcinolone Acetonide Ointment Prescription Drug Bottle
About Triamcinolone Acetonide Ointment aka Triamcinolone Ointment

What's The Definition Of The Medical Condition Triamcinolone Acetonide Ointment?

Clinical Pharmacology

CLINICAL PHARMACOLOGY Topical corticosteroids share anti-inflammatory, antipruritic and vasoconstrictive actions. The mechanism of anti-inflammatory activity of the topical corticosteroids is unclear. Various laboratory methods, including vasoconstrictor assays, are used to compare and predict potencies and/or clinical efficacies of the topical corticosteroids.There is some evidence to suggest that a recognizable correlation exists between vasoconstrictor potency and therapeutic efficacy in man. Pharmacokinetics The extent of percutaneous absorption of topical corticosteroids is determined by many factors including the vehicle, the integrity of the epidermal barrier, and the use of occlusive dressings. Topical corticosteroids can be absorbed from normal intact skin. Inflammation and/or other disease processes in the skin increase percutaneous absorption. Occlusive dressings substantially increase the percutaneous absorption of topical corticosteroids. Thus, occlusive dressings may be a valuable therapeutic adjunct for treatment of resistant dermatoses (see DOSAGE AND ADMINISTRATION). Once absorbed through the skin, topical corticosteroids are handled through pharmacokinetic pathways similar to systemically administered corticosteroids. Corticosteroids are bound to plasma proteins in varying degrees. Corticosteroids are metabolized primarily in the liver and are then excreted by the kidneys. Some of the topical corticosteroids and their metabolites are also excreted into the bile.

Clinical Pharmacology

CLINICAL PHARMACOLOGY Topical corticosteroids share anti-inflammatory, antipruritic and vasoconstrictive actions. The mechanism of anti-inflammatory activity of the topical corticosteroids is unclear. Various laboratory methods, including vasoconstrictor assays, are used to compare and predict potencies and/or clinical efficacies of the topical corticosteroids. There is some evidence to suggest that a recognizable correlation exists between vasoconstrictor potency and therapeutic efficacy in man. Pharmacokinetics: The extent of percutaneous absorption of topical corticosteroids is determined by many factors including the vehicle, the integrity of the epidermal barrier, and the use of occlusive dressings. Topical corticosteroids can be absorbed from normal intact skin. Inflammation and/or other disease processes in the skin increase percutaneous absorption. Occlusive dressings substantially increase the percutaneous absorption of topical corticosteroids. Thus, occlusive dressings may be a valuable therapeutic adjunct for treatment of resistant dermatoses (See DOSAGE AND ADMINISTRATION). Once absorbed through the skin, topical corticosteroids are handled through pharmacokinetic pathways similar to systemically administered corticosteroids. Corticosteroids are bound to plasma proteins in varying degrees. Corticosteroids are metabolized primarily in the liver and are then excreted by the kidneys. Some of the topical corticosteroids and their metabolites are also excreted into the bile.

Drug Description

Find Lowest Prices on Trianex® 0.05% (triamcinolone acetonide) Ointment, USP Proprietary Hydrous Emulsified Base DESCRIPTION Topical corticosteroids, such as Trianex® 0.05% (Triamcinolone Acetonide Ointment, USP), constitute a class of primarily synthetic steroids used as anti-inflammatory and antipruritic agents. Each gram of Trianex® 0.05% (Triamcinolone Acetonide Ointment, USP) contains 0.5 mg of Triamcinolone Acetonide USP in a waterin-oil emulsion composed of Light Mineral Oil NF, Purifi ed Water USP, White Petrolatum USP, Heavy Mineral Oil USP, Mineral Wax, and Lanolin Alcohols NF. The white ointment is for topical use only. Triamcinolone Acetonide has the molecular formula of C24H31FO6 and is designated chemically as Pregna- 1, 4-diene-3, 20-dione, 9-fl uoro-11, 21- dihydroxy - 16, 17- [(1-methylethylidene)bis (oxy)]-, (11ß, 16α)-. It has a molecular weight of 434.50 and the following structural formula:

Drug Description

Triamcinolone Acetonide (triamcinolone acetonide ointment) Ointment USP, 0.025%, 0.1% DESCRIPTION Triamcinolone Acetonide (triamcinolone acetonide ointment) Ointment USP contains Triamcinolone Acetonide (triamcinolone acetonide ointment) [Pregna-1,4-diene-3,20-dione, 9-fluoro-11,21-dihydroxy-16,17-[(1-methylethylidene)bis-(oxy)]-, (11β,16α)-], with the molecular formula C24H31FO6 and molecular weight 434.50. CAS 76-25-5. Triamcinolone Acetonide (triamcinolone acetonide ointment) Ointment USP, 0.025% contains: 0.25 mg of triamcinolone acetonide per gram in a base containing white petrolatum and mineral oil. Triamcinolone Acetonide (triamcinolone acetonide ointment) Ointment USP, 0.1% contains: 1 mg triamcinolone acetonide per gram in a base containing white petrolatum and mineral oil.

Indications & Dosage

INDICATIONS Trianex® 0.05% (Triamcinolone Acetonide Ointment, USP) is indicated for the relief of the inflammatory and pruritic manifestations of corticosteroid responsive dermatoses. DOSAGE AND ADMINISTRATION Trianex® 0.05% (Triamcinolone Acetonide Ointment, USP) is generally applied to the affected area as a thin fi lm from two to four times daily depending on the severity of the condition. Occlusive dressings may be used for the management of psoriasis or recalcitrant conditions. If an infection develops, the use of occlusive dressings should be discontinued and appropriate antimicrobial therapy instituted. HOW SUPPLIED Trianex® 0.05% (Triamcinolone Acetonide Ointment, USP) is supplied in 430 g jars (NDC 67857-806-19). KEEP THIS AND ALL DRUGS OUT OF THE REACH OF CHILDREN. You may report side effects to FDA at 1-800- FDA-1088. You may also report side effects to Promius Pharma, LLC at 1-888-966-8766. STORE AT CONTROLLED ROOM TEMPERATURE 15°– 30° C (59°– 86° F). DISPENSE IN A WELL-CLOSED CONTAINER. CAUTION: Federal law prohibits dispensing without prescription For external use only. Not for ophthalmic use. Distributed by: Promius Pharma, LLC, Princeton, NJ 08540. Manufactured by: CMP Pharma, Inc., Farmville, NC 27828. Revised: Jan 2015

Indications & Dosage

INDICATIONS Topical corticosteroids are indicated for the relief of the inflammatory and pruritic manifestations of corticosteroid-responsive dermatoses. DOSAGE AND ADMINISTRATION Apply to the affected area as a thin film as follows: Triamcinolone Acetonide (triamcinolone acetonide ointment) Ointment USP, 0.025% two to four times daily; Triamcinolone Acetonide (triamcinolone acetonide ointment) Ointment USP, 0.1% two or three times daily depending on the severity of the condition. Occlusive dressings may be used for the management of psoriasis or recalcitrant conditions. If an infection develops, the use of occlusive dressings should be discontinued and appropriate antimicrobial therapy instituted. HOW SUPPLIED Triamcinolone Acetonide (triamcinolone acetonide ointment) Ointment USP, 0.025% 80 gram tubes.........NDC 0168-0005-80 Triamcinolone Acetonide (triamcinolone acetonide ointment) Ointment USP, 0.1% 15 gram tubes.........NDC 0168-0006-15 80 gram tubes.........NDC 0168-0006-80 1 Lb jars.................NDC 0168-0006-16 Store at controlled room temperature 15°-30°C (59°-86°F). E. Fougera & CO. a division of Altana Inc., Melville, New York 11747.

Medication Guide

Overdosage & Contraindications

OVERDOSE Topically applied corticosteroids can be absorbed in sufficient amounts to produce systemic effects (see PRECAUTIONS). CONTRAINDICATIONS Trianex® 0.05% (Triamcinolone Acetonide Ointment, USP) is contraindicated in those patients with a history of hypersensitivity to any of the components of the preparation.

Overdosage & Contraindications

OVERDOSE Topically applied corticosteroids can be absorbed in sufficient amounts to produce systemic effects (See PRECAUTIONS). CONTRAINDICATIONS Topical corticosteroids are contraindicated in those patients with a history of hypersensitivity to any of the components of the preparation.

Side Effects & Drug Interactions

SIDE EFFECTS The following local adverse reactions are reported infrequently with topical corticosteroids, but may occur more frequently with the use of occlusive dressings. These reactions are listed in an approximate decreasing order of occurrence: Burning Itching Irritation Dryness Folliculitis Hypertrichosis Acneiform eruptions Hypopigmentation Perioral dermatitis Allergic contact dermatitis Maceration of the skin Secondary infection Skin atrophy Striae Miliaria DRUG INTERACTIONS No information provided.

Side Effects & Drug Interactions

SIDE EFFECTS The following local adverse reactions are reported infrequently with topical corticosteroids, but may occur more frequently with the use of occlusive dressings. These reactions are listed in an approximate decreasing order of occurrence: burning, itching, irritation, dryness, folliculitis, hypertrichosis, acneiform eruptions, hypopigmentation, perioral dermatitis, allergic contact dermatitis, maceration of the skin, secondary infection, skin atrophy, striae and miliaria. DRUG INTERACTIONS No information provided.

Warnings & Precautions

WARNINGS No information provided. PRECAUTIONS General Systemic absorption of topical corticosteroids has produced reversible hypothalamic-pituitaryadrenal (HPA) axis suppression, manifestations of Cushing's syndrome, hyperglycemia, and glucosuria in some patients. Conditions which augment systemic absorption include the application of the more potent steroids, use over large surface areas, prolonged use, and the addition of occlusive dressings. Therefore, patients receiving a large dose of a potent topical steroid applied to a large surface area or under an occlusive dressing should be evaluated periodically for evidence of HPA axis suppression by using the urinary free cortisol and ACTH stimulation tests. If HPA axis suppression is noted, an attempt should be made to withdraw the drug, to reduce the frequency of application, or to substitute a less potent steroid. Recovery of HPA axis function is generally prompt and complete upon discontinuation of the drug. Infrequently, signs and symptoms of steroid withdrawal may occur, requiring supplemental systemic corticosteroids. Children may absorb proportionally larger amounts of topical corticosteroids and thus be more susceptible to systemic toxicity (see PRECAUTIONS - Pediatric Use). If irritation develops, topical corticosteroids should be discontinued and appropriate therapy instituted. In the presence of dermatological infections, the use of an appropriate antifungal or antibacterial agent should be instituted. If a favorable response does not occur promptly, the corticosteroid should be discontinued until the infection has been adequately controlled. Laboratory Tests The following tests may be helpful in evaluating the HPA axis suppression: Urinary free cortisol test ACTH stimulation test Carcinogenesis, Mutagenesis And Impairment Of Fertility Long-term animal studies have not been performed to evaluate the carcinogenic potential or the effect on fertility of topical corticosteroids. Studies to determine mutagenicity with prednisolone and hydrocortisone have revealed negative results. Pregnancy Category C Corticosteroids are generally teratogenic in laboratory animals when administered systemically at relatively low dosage levels. The more potent corticosteroids have been shown to be teratogenic after dermal application in laboratory animals. There are no adequate and well-controlled studies in pregnant women on teratogenic effects from topically applied corticosteroids. Therefore, topical corticosteroids should be used during pregnancy only if the potential benefit justifies the potential risk to the fetus. Drugs of this class should not be used extensively on pregnant patients, in large amounts, or for prolonged periods of time. Nursing Mothers It is not known whether topical administration of corticosteroids could result in sufficient systemic absorption to produce detectable quantities in breast milk. Systemically administered corticosteroids are secreted into breast milk in quantities not likely to have a deleterious effect on the infant. Nevertheless, caution should be exercised when topical corticosteroids are administered to a nursing woman. Pediatric Use Pediatric patients may demonstrate greater susceptibility to topical corticosteroid-induced HPA axis suppression and Cushing's syndrome than mature patients because of a larger skin surface area to body weight ratio. Hypothalamic-pituitary-adrenal (HPA) axis suppression, Cushing's syndrome and intracranial hypertension have been reported in children receiving topical corticosteroids. Manifestations of adrenal suppression in children include linear growth retardation, delayed weight gain, low plasma cortisol levels, and absence of response to ACTH stimulation. Manifestations of intracranial hypertension include bulging fontanelles, headaches, and bilateral papilledema. Administration of topical corticosteroids to children should be limited to the least amount compatible with an effective therapeutic regimen.  Chronic corticosteroid therapy may interfere with the growth and development of children.

Warnings & Precautions

WARNINGS No information provided. PRECAUTIONS General Systemic absorption of topical corticosteroids has produced reversible hypothalamic-pituitary-adrenal (HPA) axis suppression, manifestations of Cushing's syndrome, hyperglycemia, and glucosuria in some patients. Conditions which augment systemic absorption include the application of the more potent steroids, use over large surface areas, prolonged use, and the addition of occlusive dressings. Therefore, patients receiving a large dose of a potent topical steriod applied to a large surface area or under an occlusive dressing should be evaluated periodically for evidence of HPA axis suppression by using the urinary free cortisol and ACTH stimulation tests. If HPA axis suppression is noted, an attempt should be made to withdraw the drug, to reduce the frequency of application, or to substitute a less potent steroid. Recovery of HPA axis function is generally prompt and complete upon discontinuation of the drug. Infrequently, signs and symptoms of steroid withdrawal may occur, requiring supplemental systemic corticosteroids. Children may absorb proportionally larger amounts of topical corticosteroids and thus be more susceptible to systemic toxicity (See PRECAUTIONS-Pediatric Use). If irritation develops, topical corticosteroids should be discontinued and appropriate therapy instituted. In the presence of dermatological infections, the use of an appropriate anti-fungal or antibacterial agent should be instituted. If a favorable response does not occur promptly, the corticosteroid should be discontinued until the infection has been adequately controlled. Laboratory Tests The following tests may be helpful in evaluating the H PA axis suppression: Urinary free cortisol test; ACTH stimulation test. Carcinogenesis, Mutagenesis, and Impairment of Fertility Long-term animal studies have not been performed to evaluate the carcinogenic potential or the effect on fertility of topical corticosteroids. Studies to determine mutagenicity with prednisolone and hydrocortisone have revealed negative results. Pregnancy Category C Corticosteroids are generally teratogenic in laboratory animals when administered systemically at relatively low dosage levels. The more potent corticosteroids have been shown to be teratogenic after dermal application in laboratory animals. There are no adequate and well-controlled studies in pregnant women on teratogenic effects from topically applied corticosteroids. Therefore, topical corticosteroids should be used during pregnancy only if the potential benefit justifies the potential risk to the fetus. Drugs of this class should not be used extensively on pregnant patients, in large amounts, or for prolonged periods of time. Nursing Mothers It is not known whether topical administration of corticosteroids could result in sufficient systemic absorption to produce detectable quantities in breast milk. Systemically administered corticosteroids are secreted into breast milk in quantities not likely to have a deleterious effect on the infant. Nevertheless, caution should be exercised when topical corticosteroids are administered to a nursing woman. Pediatric Use Pediatric patients may demonstrate greater susceptibility to topical corticosteroid-induced H PA axis suppression and Cushing's syndrome than mature patients because of a larger skin surface area to body weight ratio. Hypothalamicpituitary-adrenal (HPA) axis suppression, Cushing's syndrome, and intracranial hypertension have been reported in children receiving topical corticosteroids. Manifestations of adrenal suppression in children include linear growth retardation, delayed weight gain, low plasma cortisol levels, and absence of response to ACTH stimulation. Manifestations of intracranial hypertension include bulging fontanelles, headaches, and bilateral papilledema. Administration of topical corticosteroids to chil-dren should be limited to the least amount compatible with an effective therapeutic regimen. Chronic corticosteroid therapy may interfere with the growth and development of children.

More Medical Conditions

A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z

Medical Conditions Definitions Of The Day